Icom IC-FR5000 Series Sales Handbook page 26

Vhf and uhf fm repeaters
Table of Contents

Advertisement

Port Setting :
Port Setting :
Port Setting :
Port Setting :
Assign a function to each port;
For [Ext.I
For [
Ext.I/O 15 to 25]
/O 15 to 25]
For [
For [
Ext.I
Ext.I
/O 15 to 25]
/O 15 to 25]
• In/Out
In/Out
In/Out
In/Out
Select the type of the assignable function from Input
and Output.
• Active Logic
Active Logic
Active Logic (Available when "Output" is selected
Active Logic
In/Out as above)
In/Out
In/Out
In/Out
Select the active logic for the D-sub 25 pin output
from High and Low.
Function- - - - When "Input" is selected in In/Out
Function
When "Input" is selected in In/Out
Function
Function
When "Input" is selected in In/Out
When "Input" is selected in In/Out
• Null
Null
Null
Null
No function.
• MCH Select : 1/2/3/4/5
MCH Select : 1/2/3/4/5
MCH Select : 1/2/3/4/5
MCH Select : 1/2/3/4/5
You can select the desired memory channel with the
function. Activate the desired MCH Selects assigned
ports to make the Ext CH No. You can make the Ext
CH No. one of the 32 pre-programmed memory
channels. (see table below) [0]: Hi-Z, [1]: 0 V
MCH Select : 1
MCH Select : 1
MCH Select : 1
MCH Select : 1
MCH Select : 2
MCH Select : 2
MCH Select : 2
MCH Select : 2
MCH Select : 3
MCH Select : 3
MCH Select : 3
MCH Select : 3
MCH Select : 4
MCH Select : 4
MCH Select : 4
MCH Select : 4
MCH Select : 5
MCH Select : 5
MCH Select : 5
MCH Select : 5
MCH Select
MCH Select
MCH Select
MCH Select
MCH Select
MCH Select
MCH Select
MCH Select
CH
CH
CH
CH
CH
CH
CH
CH
5 5 5 5
4 4 4 4
3 3 3 3
2 2 2 2
1
0
0
0
0
2
0
0
0
0
3
0
0
0
1
4
0
0
0
1
5
0
0
1
0
6
0
0
1
0
7
0
0
1
1
8
0
0
1
1
9
0
1
0
0
10
0
1
0
0
11
0
1
0
1
12
0
1
0
1
13
0
1
1
0
14
0
1
1
0
15
0
1
1
1
16
0
1
1
1
• EPTT
EPTT
EPTT
EPTT
When the port is activated, the Ext. PTT (EPTT)
function is turned "ON".
• Repeat Disable
Repeat Disable
Repeat Disable
Repeat Disable
When the port is activated, the repeater operation is
disabled.
•TX Disable
TX Disable
TX Disable
TX Disable
When the port is activated, the transmission is
disabled.
•Mic Mute
Mic Mute
Mic Mute
Mic Mute
When the port is activated, the connected
microphone is muted.
•Ext. Key
Ext. Key
Ext. Key
Ext. Key
You can use the port as the customized key. The
same functions in the Key Assign are assignable to
the port.
Connector Description
+ 1 CH
+ 2 CH
+ 4 CH
+ 8 CH
+ 16 CH
MCH Select
MCH Select
MCH Select
MCH Select
MCH Select
MCH Select
MCH Select
MCH Select
CH
CH
CH
CH
CH
CH
CH
CH
1 1 1 1
5 5 5 5
4 4 4 4
3 3 3 3
2 2 2 2
0
17
1
0
0
0
1
18
1
0
0
0
0
19
1
0
0
1
1
20
1
0
0
1
0
21
1
0
1
0
1
22
1
0
1
0
0
23
1
0
1
1
1
24
1
0
1
1
0
25
1
1
0
0
1
26
1
1
0
0
0
27
1
1
0
1
1
28
1
1
0
1
0
29
1
1
1
0
1
30
1
1
1
0
0
31
1
1
1
1
1
32
1
1
1
1
Function
Function- - - - When "Output" is selected in In/Out
Function
Function
When "Output" is selected in In/Out
When "Output" is selected in In/Out
When "Output" is selected in In/Out
• Null
Null
Null
Null
No function.
• Busy
Busy
Busy
Busy
Acts when receiving a carrier signal that is stronger
than the SQL level.
• Analog Audible
Analog Audible
Analog Audible
Analog Audible
Acts when the mute is released by receiving an
analog signal.
• Digital Audible
Digital Audible
Digital Audible
Digital Audible
Acts when the mute is released by receiving a digital
signal.
• Mic Mute
Mic Mute
Mic Mute
Mic Mute
Acts while the connected microphone's mute is
released.
• Hanger
Hanger
Hanger
Hanger
Acts while the connected microphone is put down on
its hanger (hanger-on).
• PTT
PTT
PTT
PTT
Acts while pushing the connected microphone's [PTT]
or Ext.PTT (EPTT).
• TX TX TX TX
Acts while the repeater is transmitting.
• Low Voltage 1/2
Low Voltage 1/2
Low Voltage 1/2
Low Voltage 1/2
Acts when the repeater's voltage is lower than the
Acts when the repeater's voltage is lower than the
1 1 1 1
Low Voltage 1/2
Low Voltage 1/2
Low Voltage 1/2
Low Voltage 1/2 in the Common screen respectively.
0
• Over Voltage
Over Voltage
Over Voltage
Over Voltage
1
Acts when the repeater's voltage is overvoltage.
0
• Final Protect
Final Protect
Final Protect
Final Protect
1
0
Acts when the final protect is activated.
1
• Fan State
Fan State
Fan State
Fan State
0
Acts while the FAN works improperly.
1
• RX/TX Unlock
RX/TX Unlock
RX/TX Unlock
RX/TX Unlock
0
1
Acts while the RX/TX PLL is unlocked.
0
• P0/1/2/3/4 Monitor
P0/1/2/3/4 Monitor
P0/1/2/3/4 Monitor
P0/1/2/3/4 Monitor
1
Outputs the customized key (P0 to 4) condition when
0
each key is pushed.
1
0
For [Ext. D/A 10]
For [Ext. D/A 10]
For [Ext. D/A 10]
For [Ext. D/A 10]
1
The Analog Output port can output the Analog signal to
the D/A port.
• Null
Null
Null
Null
No function.
• Power
Power
Power- - - - supply Voltage
Power
supply Voltage
supply Voltage
supply Voltage
Outputs the VIN (proportionate to the power-supply
voltage).
• Temperature
Temperature
Temperature
Temperature
Outputs the TEMPS (proportionate to the
temperature).
• RSSI
RSSI
RSSI
RSSI
Outputs the SD (proportionate to the received
signal's RSSI voltage).
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr6000 seriesIc-fr6000 series

Table of Contents