Download Print this page
Icom IC-FR5200H Instructions

Icom IC-FR5200H Instructions

Vhf/uhf repeater

Advertisement

Quick Links

CONNECTION
D Rear panel connection
ACC CONNECTOR
Used for external equipment
To a [LAN] port of the
control.
IC-FC5000E (dPMR) or a
To a TX
PC console through a
To an RX antenna*
1
antenna*
1
Hub or a router (NXDN)*
IF
EXTERNAL SPEAKER
1
*
// only for the NXDN version //
Connect a 4 ø external speaker.
The illustration to the right
describes one example of a
connection for trunking mode
operation.
Up to 30 repeaters can be
daisy-chained.
SP-35/SP-35L
PC console connection (only for NXDN)
To an Ethernet port
Hub*
1
1
PC console*
1
*
Purchase separately.
2
*
See the illustration to the left for the PC console connection
through a Hub (NXDN).
To the [LAN] connector
of the repeater
• Grounding
To prevent electrical shock, television interfer-
ence (TVI), broadcast interference (BCI) and
other problems, ground the repeater using the
GROUND [GND] terminal on the rear panel.
For best results, connect a heavy gauge wire or strap to a
long ground rod. Make the distance between the [GND] ter-
minal and ground rod as short as possible.
R WARNING! NEVER connect the [GND] terminal to a
gas or electric pipe, since the connection could cause an
explosion or electric shock.
• Power supply
Make sure the repeater's power is OFF when connecting a
DC power cable.
CAUTION: Voltages greater than 16 V DC will damage the
repeater. Check the source voltage before connecting the
power cable.
AC outlet
DC power supply *
NXDN: 13.6 V
dPMR: 13.2 V
(at least 20 A)
Red
Black
+
_
2
.
DC power
cable
Repeater
LAN
BUS-2
BUS-1
CAT-5 straight cable*
LAN
BUS-2
BUS-1
LAN
BUS-2
BUS-1
• Antenna
For repeater communications, an antenna is a critical com-
ponent, along with output power and sensitivity. Select
antenna(s), such as a well-matched 50 ø antenna, and feed-
line. A 1.5:1 or better Voltage Standing Wave Ratio (VSWR)
is recommended for a desired band. Of course, the transmis-
sion line should be a coaxial cable.
If you want to connect only one antenna for both transmission
and reception, use a third-party duplexer.
CAUTION: Protect the repeater from lightning by using a
lightning arrestor.
NOTE: There are many publications that describe proper
antennas and their installation. Check with your local dealer
for more information and recommendations.
– 4 –
1
VHF REPEATER
Iç-FR5200H
UHF REPEATER
Iç-FR6200H
FOREWORD
This instruction sheet includes some functions that are us-
able only when they are preset by your dealer. Ask your deal-
er for details.
SUPPLIED ACCESSORIES
Handles
For the handles installation
Spacers
1
Screws
DC power cable
Rack
1
*
Used for labelling the program-
mable function keys according
to their assinged functions.
Icom is not responsible for the destruction, damage to, or
performance of any Icom or non-Icom equipment, if the
malfunction is because of:
• Force majeure, including, but not limited to, fires, earth-
quakes, storms, floods, lightning, other natural disasters,
disturbances, riots, war, or radioactive contamination.
• The use of Icom transceivers with any equipment that is
not manufactured or approved by Icom.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incor-
porated (Japan) in Japan, the United States, the United Kingdom, Germany,
France, Spain, Russia, and/or other countries.
dPMR and the dPMR logo are trademarks of the dPMR MoU Association
NXDN is a trademark of Icom Incorporated and JVC Kenwood Corporation.
All other products or brands are registered trademarks or trademarks of their
respective holders.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
INSTRUCTIONS
Thank you for choosing this Icom product. READ ALL
INSTRUCTIONS carefully and completely before us-
ing this product.
• SP-35/SP-35L
external speakers
Input impedance :
Maximum input power : 7 W
• HM-152
hand microphone
• SM-26
desktop microphone
Some options may not be available in some countries. Please
ask your dealer for details.
Allen wrench
FUSE REPLACEMENT
If a fuse blows or the repeater stops functioning, try to find
the source of the problem, and then replace the damaged
fuse with a new rated one.
❑ Fuse rating: 30 A
Spare fuse (FGB01 30 A)
USE only a 30 A fuse.
Function name
stickers*
1
KEY SEAL
The crossed-out wheeled-bin symbol on your
product, literature, or packaging reminds you
that in the European Union, all electrical and
electronic products, batteries, and accumula-
tors (rechargeable batteries) must be taken to
designated collection locations at the end of
their working life.
Do not dispose of these products as unsorted municipal
waste. Dispose of them according to the laws in your area.
– 1 –
OPTIONS
4 ø
DISPOSAL
A-7189D-2EX-q
Printed in Japan
© 2014–2017 Icom Inc.

Advertisement

loading

Summary of Contents for Icom IC-FR5200H

  • Page 1 Icom. electronic products, batteries, and accumula- • Power supply Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incor- tors (rechargeable batteries) must be taken to Make sure the repeater’s power is OFF when connecting a...
  • Page 2 PANEL DESCRIPTION PANEL DESCRIPTION (Continued) D Front panel D Rear panel ¬ DC INPUT ¬ BUS-2 BUS-1 Function – FUSE Speaker display FUSE SPEAKER * only for the NXDN version q D-SUB 25-PIN [ACC] y BUS CONNECTORS [BUS-1]/[BUS-2] // only for the NXDN version // Connects an external unit.

This manual is also suitable for:

Ic-fr6200h