PERSONAL ATTACK (PA) ALARM

An Alarm can be immediately triggered at any time
(whether the system is Armed or Disarmed) in the
event of threat or danger by activating a Personal
Attack (PA) switch on either the Remote Control or
the Control Panel as follows:
a.
Press and hold the
3 seconds or
b.
Press and hold the
approximately 3 seconds on the Control
Panel.
The alarm will continue either for the alarm duration
after which the system will automatically reset or until
the system is disarmed. All zone, Fire and Tamper
LEDs will flash together continuously.
After disarming the system press
indication.

DEVICE TAMPER

If the battery cover of any device (except a Remote
Control) is removed or if the Siren or Control Panel
are removed from the wall then an alarm will
immediately occur (unless the system is in Test or
Program Modes), even if the system is Disarmed.
The Tamper LED on the Control Panel will illuminate
to indicate the Tamper Alarm has been activated.
After disarming the system press
indication.
Note: The Tamper protection facility on the Siren
operates independently of the Control Panel. If the
Tamper on the Siren is activated this will not be
indicated at the Control Panel.

FIRE ZONE(s)

The dedicated Fire zone operates on a 24 hour
basis. (i.e. Receipt of an alarm signal from a
smoke/fire alarm will immediately trigger an alarm
irrespective of systems armed/disarmed status
unless the system is in Program or Test modes).
The Fire LED will flash continuously.
After disarming the system press
indication.
30
button for
!
9
button for
to clear the
ESC
to clear the
ESC
to clear the
ESC
Notes:
1. The fire alarm sound will be different to that
generated from an intruder alarm.
2. The fire alarm will sound at the control panel only.
3. The fire alarm at the control panel will be started
and stopped under command from the smoke
detector. It will not be under control of the
programmed alarm duration, i.e. if the smoke
alarm stops sounding then the alarm at the
control panel will also stop.
4. The alarm at the control panel may also be
stopped by disarming the system in the
normal way.

SIREN SERVICE MODE

In order to remove the Solar Siren from the wall to
change the batteries, it is necessary to place the
Siren into Service mode to prevent the Tamper
switch on the Siren operating and triggering an
alarm. When you have completed any alterations to
the system you must remember to switch the siren
back into Operating Mode.
The Siren can be switched into Service mode using
either the Remote Control or Control Panel as follows:
Remote Control:
Press and hold the
approximately 5 seconds.
After 5 seconds, the siren will produce two
short beeps followed 1 second later by a single
long beep. The Siren LEDs will flash together
in conjunction with the beeps.
Control Panel:
With the system in Standby Mode with the
Power LED ON:
,
Press
?
User Access Code
to enter Test Mode. The Arm and Part-Arm LEDs
will flash.
Press
8
to switch the Siren into Service
ENTER
Mode.
Zone 6 LED will illuminated for 3 seconds while
the "Siren Service Mode ON" signal is transmitted.
button for
,
?
?
?
ENTER