LED on Remote Control not illuminating, or
is dim when unit is operated.
1. Ensure battery is fitted with correct polarity.
2. Ensure battery holder connections are making
good contact with the battery.
3. Battery flat - replace battery.
PIR Detector false alarming.
1. Ensure that the detector is not pointing at a
source of heat or a moving object.
2. Ensure that the detector is not mounted above a
radiator or heater.
3. Ensure that the detector is not facing a window
or in direct sunlight.
4. Ensure that the detector is not in a draughty area.
5. Sensitivity set too HIGH - reset to LOW
sensitivity. (i.e. SW3 to down position).
PIR Detector not detecting a person's
movement.
1. Ensure the battery clip is securely connected.
2. Ensure 'ID Code' is learnt by the Control Panel
into a particular zone.
3. Sensitivity set too LOW - reset to HIGH
sensitivity. (i.e. SW3 to up position).
4. Ensure that detector is mounted the correct way
up, (i.e. with detection window at the bottom).
5. Ensure that the detector is mounted at the
correct height, (i.e. 2-2.5 metres).
6. Allow up to 3 minutes for detector to stabilize
and become fully operational. Leave the area
for this period.
7. Ensure detector is within effective radio range of
the Control Panel and is not mounted close to
metal objects which may interfere with Radio
transmission.
PIR Detector LED flashes on detection of
movement, (device in normal operation mode).
1. PIR still in Walk Test Mode for fixed 5 minutes if
the PCB button was activated.
2. Low battery - replace battery.
Door / Window Detector not working.
1. Ensure that Magnet is correctly positioned in
relation to Detector and that the gap between
Magnet and Detector is less than 10mm.
2. Ensure batteries are fitted with correct polarity
(correct way around).
3. Ensure battery holder connections are making
good contact with the batteries and Circuit Board.
4. Ensure 'ID Code' is learnt by the Control Panel
into a particular zone.
5. If an additional wired Magnetic Contact is
connected:
a. Check that both contacts are closed.
b. Check that additional contact is correctly wired
and switch SW3 set to the INT./EXT. position.
6. Ensure detector is within effective radio range of
Control Panel and is not mounted close to metal
objects which may interfere with Radio
transmission.
Door / Window Detector false alarming.
1. Ensure that magnet is correctly positioned in
relation to detector.
2. Ensure that gap between magnet and detector
is less than 10mm.
3. Tamper switch below battery cover is not
depressed - check battery cover is fitted
correctly and that fixing lugs are not broken.
LED on Door / Window Detector illuminating
when door or window is opened.
1. Low battery - replace batteries.
35