Response SL3 Installation And Operating Manual page 2

6 zone wireless security alarm
Table of Contents

Advertisement

FOREWORD
All devices in this wireless Alarm System are
designed and manufactured to provide long reliable
service. The system is designed for ease of
installation using only conventional domestic tools.
However, it is essential that the installer reads and
fully understands the advice and procedures
contained in this manual and plans the system before
proceeding with the installation.
During installation, it is important that the procedures
described in this manual are followed in sequence.
This manual should be retained in a safe place
for future reference.
IMPORTANT: All devices, with the exception of the
External Siren are suitable for mounting in dry
interior locations only.
IMPORTANT:
LOCAL AUTHORITY REGULATIONS AND
LEGISLATION
This alarm system should be installed and
operated in accordance with the requirements of
any current local and / or national regulations and
legislation. We recommend that you contact your
authority to obtain details of your area's
requirements regarding intruder alarm installations.
For example in Belgium, the installation and use
of an alarm system including notification by
telephone (Voice Dialler) functionality and the
optional use of an external siren is controlled by
Belgium legislation "KB" of 19/06/2002.
DECLARATION
Novar ED&S hereby declares that this wireless alarm
system is in compliance with the essential
requirements and other relevant provisions of the
Radio and Telecommunications Terminal Equipment
(R&TTE) directive, 1999/5/EC.
Tools and Equipment Required:
No.0 Philips Screwdriver
No.1 Philips Screwdriver
No.2 Philips Screwdriver
Small Spirit Level
2
Bradawl
Drill
3mm Drill Bit
5 & 6mm Masonry Drill Bits
DEVICE RANGE
The quoted range of the system devices (see component
specification on rear cover) is measured in ideal
conditions. Any solid object (e.g. walls, ceilings,
reinforced PVC doors etc) placed between the transmitter
and Receiver device will reduce the radio range.
The amount by which the range will be reduced is
dependant upon the nature of the barrier.
For example:
Wall Type
Dry-lined partition wall:
Single layer brick wall:
Double layer brick wall:
Metal panel/radiator:
Note: The effect on the range of multiple walls is
cumulative, i.e. if there are 2 brick walls in the way,
the range will be reduced by up to 40% by each wall.
SYSTEM SECURITY
This system has been designed to both detect
intruders and act as a strong deterrent to would-be
intruders when installed correctly.
We recommend that your Alarm is used in conjunction
with good physical protection such as security window
and door locks.
All units in the system are encoded to operate together
using a 20 bit House Code.
The system is operated from one or more Remote
Control Units and/or Keypads - depending on which
system and/or accessories purchased.
SAFETY
Always follow the manufacturers advice when using
power tools; steps, ladders etc. and wear suitable
protective equipment (e.g. safety goggles) when
drilling holes etc.
Before drilling holes in walls, check for hidden
electricity cables and water pipes, the use of a
cable/pipe locater maybe advisable if in doubt.
When using ladders, ensure that they are positioned
on a firm stable surface at the correct angle and
suitably secured before use.
The use of ear defenders is advisable when working
in close proximity to the Siren due to the high sound
level produced by this device.
Range Reduction
10 - 30%
20 - 40%
30 - 70%
90 - 100%

Hide quick links: