Learning Fire Zones - Response SL3 Installation And Operating Manual

6 zone wireless security alarm
Table of Contents

Advertisement

3.
Press
again within 15 seconds to confirm
ENTER
and erase the device links.
The flashing zone LEDs will extinguish.
Note: If the erase is not confirmed within
15s the LEDs will stop flashing and remain
illuminated. All links will remain intact and
will not be erased.
4.
Press
to save new settings and return to
ENTER
step1 or press
ESC
5.
If after adding a detector, no more detectors
require adding, then press
Mode.

LEARNING FIRE ZONES

A maximum of 3 Smoke detectors can be linked to the
dedicated Fire zone.
1.
Place the Control Panel into Learn Mode as follows:
With the system in Standby
,
Press
?
User Access Code
The Arm and Part-Arm LEDs will illuminate and
all Zone, Fire and tamper LEDs will flash together.
1
7
2.
Press
The Tamper LED will flash continuously to
indicate the system is in device Learn Mode.
The current number of Smoke Detectors already
linked into the Fire zone will be indicated on the zone
LEDs. For example if there are two smoke detectors
linked, then zone LEDs 1 and 2 will be illuminated.
The panel will now listen for valid signals from new
Smoke Detectors to link to the Fire zone.
Notes:
– PIR or MAG detectors cannot be added to the
Fire zone and the system will prevent this.
– The Panel will remain in Learn Mode for 30s.
If a valid signal is not received from a Smoke
Detector within 30s it will automatically exit
Learn Mode and return to the top level of
Program Mode.
18
to exit without saving.
to exit Learn
ESC
,
?
?
?
ENTER
To link a new Smoke Detector to the
Control Panel:
3.
Activate the Smoke detector via the test button.
If the detector is new and not already linked on
the fire zone the panel will produce a two short
beeps and the next available zone LED will start
flashing, (once every second).
Notes:
– If the smoke detector is already linked to
the control panel or if there are already
the maximum 3 smoke detectors linked to
the fire zone then the panel will produce
a single long beep received signal from
remote control will be ignored.
– PIR or MAG detectors cannot be linked
to the Fire zone and the system will
prevent this.
4.
Confirm the new device ID code activating the
same new smoke detector via the test button
within 15 seconds.
The panel will produce three short beeps and
the zone LED will stop flashing and remain ON.
Note: If the confirmation signal is not received
within 15s the flashing LED will stop flashing
and turn off. The panel will exit to the top level
of Learn Mode without saving any changes.
The learning process will need to started again
to learn the new device into memory.
The ID code of the new Smoke detector is now
stored in memory ready for saving.
5.
Press
to save new settings and exit or
ENTER
6.
Press
to exit without saving.
ESC
To delete all linked Smoke Detectors from
the Control Panel:
7.
Press
All illuminated zone LEDs indicating linked
devices will start flashing, (once every second).
8.
Press
again within 15s to confirm and
ENTER
erase the device links.