Testing The Magnetic Contact Detectors; External Solar Siren; Positioning The Solar Siren - Response SA3 E PLUS Installation And Operating Instructions Manual

6 zone wirefree alarm system with voice dialler
Table of Contents

Advertisement

8. Slide the two batteries supplied into the battery
holder, ensuring that the positive (+) side is
uppermost on each battery as it is installed.
9. Carefully refit the battery holder onto the Detector
ensuring that the spring connectors slide onto
either side of the circuit board.
10. Fit the battery cover into position on the Magnetic
Contact Detector.
Testing the Magnetic Contact
Detectors
Ensure that the system is in Test mode.
1. Put the Control Panel into "Walk Test" mode by
pressing
1
on the Control Panel.
The Panel will beep and the Zone 1 LED will
illuminate.
2. Remove the battery cover from the Magnetic
Contact Detector.
The LED on the Detector will illuminate for approx.
1 second as the battery cover is removed and the
tamper switch is activated. In addition, the Control
Panel will beep twice to indicate that the alarm
signal has been received and the Tamper LED will
illuminate.
3. Open the door/window to remove the magnet from
the Detector.
s the magnet is moved away from the Detector
the LED will illuminate for approximately 1 second
to indicate that the Detector has been triggered.
In addition, the Control Panel will beep twice to
indicate that the alarm signal has been received
and the appropriate zone LED, which the Detector
is set for, will illuminate.
4. If any external Magnetic Contact Detectors are
connected to the Detector, operate these one at a
time. Each time a contact is opened the LED on
the Detector should illuminate for 1 second to
indicate that it has been triggered.
5. Replace the battery cover on the Detector.
6. Press
on the Control Panel to exit Walk Test.
ESC

External Solar Siren

The Siren and Solar Panel are all encapsulated within
a tough polycarbonate housing. This housing provides
full protection against adverse weather conditions.
n LED/Strobe unit is built into the siren to act as a
visible deterrent/indication that the system is active.
The Strobe LEDs will slowly and alternately flash
whether the system is armed or disarmed. However,
during an alarm condition the Strobe LEDs will flash
rapidly.
n integral anti-tamper switch provides additional
security protection to the Solar Siren and will
immediately generate a full alarm should any
unauthorized attempt be made to interfere with and
remove the Solar Siren cover.
The Solar Siren is powered by a high capacity battery.
Solar Panel mounted on the top of the housing
charges the battery during daylight hours.
darkness, only a small amount of energy is required to
operate the Solar Siren unit.
n
lkaline 9V PP3 battery is supplied in the Solar
Siren to boost the initial power to the unit when the
system is first activated until the Solar Panel charges
the main battery.

Positioning the Solar Siren

The Solar Siren should be located in a prominent
position so that it can be easily seen and heard. The
Solar Siren should be mounted on a sound flat surface
so that the rear tamper switch is not activated when
mounted. Ensure that the tamper switch does not fall
into the recess between brick courses as this could
prevent the switch from closing and give a permanent
tamper signal.
lthough the Solar Siren is designed to work on any
aspect wall, for optimum performance you should
refrain from siting the unit on a north facing wall,
where possible.
Shadows cast by neighbouring walls, trees and roof
overhangs should also be avoided. If the Solar Siren
is to be mounted below the eaves, it should be
positioned a distance of at least twice the width of the
eaves overhang below the eaves. Remember that in
winter the sun is lower in the sky and you should avoid
winter shadows where possible.
14
During

Advertisement

Table of Contents
loading