Advertisement

Setting the OFF delay time

Set this item to delay the timing that the OUTPUT signal turns OFF.
OUTPUT ON at OK judgment in continuous measurement
Judged as NG
OFF
OUTPUT
ON
MENU Mode-[SYS2]-[OUTPUT]-[OFF DELAY]
Setting
0 to 255 (default value:0)
Set the time (ms) to delay turning OFF of the OUTPUT signal.

Settings during application extended connection

These menus are displayed only when Amplifier Units are gang-mounted.
Set to the all gang-mounted Amplifier Units.
Example 1)
AMP2: TRIG signal input, AMP2: Output of overall
judgment result
Example 2)
AMP2: TRIG signal input, AMP2: Output of overall
judgment result
Settings during application extended connection
Judged as OK
Delay time
Description
TRIG
HEAD
OUTPUT
TRIG
HEAD
OUTPUT
Judged as NG