Can I turn LED light emission of the Sensor
Head OFF?
What should I do to set the measurement
time as short as possible?
Teaching is not going well. What should I
do?
ZFV
80
User's Manual
Question
Yes, you can.
[CUSTM]-[Set LIGHT] to [0000].
There are two ways of setting a shorter measurement time:
• [Set CUSTM]-[IMAGE RATE] to [HIGH SPEED]. Note, however,
that image processing becomes rougher, and measurement
accuracy drops.
• Switch the screen display during measurement to "Display only
image".
The measurement time can be reduced proportionate to the
reduction in display time.
• Workpiece move teaching mode
A probable cause is that the workpiece is not properly in the
teaching area as intended.
Change to the workpiece stop teaching mode or teaching by key
operation.
• A probable cause is that teaching is not successful because an
image is too dark or too bright.
Adjust light emission at [CUSTM]-[LIGHT] so that the workpiece
is projected clearly, and execute teaching again.