Omron ZFV - DATASHEET 2 Datasheet

Smart sensors (with ultra-high-speed ccd camera)

Advertisement

Smart Sensors (with Ultra-High-Speed CCD Camera)
ZFV Series

Ordering Information

Sets of Sensor Head and Amplifier Unit
Type
Narrow View/Single Function
Narrow View/Standard
Wide View/Single Function
Wide View/Standard
Sensor Heads
Appearance
Narrow View
Wide View
Amplifier Units
Appearance
Single Function
Standard
NPN
ZFV-R1010
ZFV-R1020
ZFV-R5010
ZFV-R5020
Type
Working length
34 to 49 mm (variable)
38 to 194 mm (variable)
Type
Power supply
24 VDC ± 10%
Smart Sensors (with Ultra-High-Speed CCD Camera)
PNP
ZFV-R1015
ZFV-R1025
ZFV-R5015
ZFV-R5025
Sensing area
5 × 4.6 mm (H × V) to
9 × 8.3 mm (H × V)
10 × 9.2 mm (H × V) to
50 × 46 mm (H × V)
Output type
NPN
PNP
NPN
PNP
Model
ZFV-SR10
ZFV-SR50
Model
ZFV-A10
ZFV-A15
ZFV-A20
ZFV-A25
ZFV Series
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron ZFV - DATASHEET 2

  • Page 1: Ordering Information

    Sensor Heads Appearance Type Working length Sensing area Model 5 × 4.6 mm (H × V) to Narrow View 34 to 49 mm (variable) ZFV-SR10 9 × 8.3 mm (H × V) 10 × 9.2 mm (H × V) to...
  • Page 2: Specifications

    Approx. 200 mA Dielectric strength 1,000 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 150 Hz, 0.35-mm single amplitude, 10 times each in X, Y, and Z directions for 8 min (destruction) Shock resistance (destruction) 150 m/s , three times each in six directions (up/down, left/right, forward/backward) Operating: 0 to 40°C, Storage: −25 to 65°C (with no icing or condensation)
  • Page 3 15 max. (ZFV: 5 Units max., ZS-LDC: 9 Units max., ZS-MDC (See note 2.): 1 Unit max.) connected External Amplifier Unit setting data can be saved to the memory card as bank data. Reading bank data enables bank switching. bank function...
  • Page 4 Dimensions Note: All units are in millimeters unless otherwise indicated. Sensor Heads Two, M4 ZFV-SR@ Depth: 6 17.9 1/4-20UNC Depth: 6 30.1 Mounting Hole Dimensions Two, M4 Mounting Bracket can be attached to any side. 20±0.1 67.9 R6.5 17.9 Heat-resistive vinyl-insulated cable (6.36)
  • Page 5: About The I/O Cable

    Which mode of measure- malfunction or damage. ment is to be performed in is selected in the menu. BANK1 (bank switching input 1) OUTPUT (control output) BANK2 (bank switching input 2) This outputs judgment results.
  • Page 6: I/O Circuit Diagrams

    BANK2 BANK3 PNP output type (ZFV-A15/A25) Brown Power supply (24VDC) Yellow TEACH Pink TRIG Gray BANK1 Green BANK2 BANK3 Blue GND(0V) Light blue ERROR 24VDC Orange ENABLE Load Black OUTPUT Load Load ZFV Series Smart Sensors (with Ultra-High-Speed CCD Camera)
  • Page 7: Timing Charts

    Make sure that the workpiece to be taught is in the teaching area. Input the TRIG signal from the outside. The ENABLE signal turns ON after teaching is completed. At this timing, check the state of the ERROR signal. When teaching has been completed successfully, the ERROR signal stays OFF.
  • Page 8 Workpiece move teaching Use this teaching mode when the object cannot be stopped. Teaching processing is divided up and performed in synchronous with the TRIG signal input after the TEACH signal is input from the outside. Teaching must be processed six times.