Example 1
In this configuration, multiple parts of an image from a single Sensor Head are mea-
sured and multiple inspection item are performed.
Example) Inspection of the number of leads
Example 2
In this configuration, multiple Sensor heads are used to simultaneously inspect multiple
locations on a workpiece.
When the TRIG signal is input from a single specified Amplifier Unit, the connected
Amplifier Unit starts sensing immediately. The result of sensing is integrated on the
Amplifier Unit to which the TRIG signal was input, and is output as a total judgment
result.
Example) Alignment of products
Section 1