System Settings And Auto Wait Time Setting; System Settings - Omron CJ - 12-2004 Manual

Id sensor units
Table of Contents

Advertisement

System Settings and Auto Wait Time Setting

5-3

System Settings and Auto Wait Time Setting

5-3-1

System Settings

Communications Test
Mode Switch Setting
Verification Setting
56
Parameter settings (including System Settings and an Auto Wait Time Set-
ting) can be adjusted to the user application to optimize the performance and
reliability of the ID Sensor Unit. Although the default settings can be used for
most applications without any problems, the parameters can be changed to
optimize the system.
The communications test mode switch on the Unit's front panel can be used
to enable and disable the communications test. The communications test
mode switch can be set to disable test mode to prevent accidentally entering
test mode.
DM Area address
Head 1 of
Head 2 of
CS1W-
CS1W-
V600C11,
V600C12
CS1W-
or CJ1W-
V600C12,
V600C12
CJ1W-
V600C11,
or CJ1W-
V600C12
m
m + 100
Verification can be enabled for write operations, or verification can be dis-
abled to shorten the communications time. The verification setting is valid for
all commands except for Read and Data Check with a processing specifica-
tion of verification.
DM Area address
Head 1 of
Head 2 of
CS1W-
CS1W-
V600C11,
V600C12
CS1W-
or CJ1W-
V600C12,
V600C12
CJ1W-
V600C11,
or CJ1W-
V600C12
m
m + 100
Bit No.
Description
08 to
0
Communications test mode
11
switch enabled.
1
Communications test mode
switch disabled. (Always Nor-
mal Mode.)
Bit No.
Description
04 to
0
Verify write operations.
07
1
Do not verify write operations.
Section 5-3
Default
0
(Enabled)
Default
0
(Verifica-
tion)