Setting the System Environment

Adjusting the measurement speed

Set the resolution of the input image.
Change the resolution according to the required precision and speed of measurement.
MENU Mode-[SYS1]-[IMAGE RATE]
Setting
FINE
Select this when performing measurement by a high-precision image. Note, how-
ever, that it takes longer to perform measurements.
NORMAL (default value)
Standard
HIGH SPEED
Select this to perform high-speed measurement. Note, however, that images are
rougher.

Selecting the measurement timing

Set the timing that measurement is executed.
MENU Mode-[SYS1]-[MEAS TYPE]
Setting
TRIG (default value)
Synchronous measurement
Measurement is performed in synchronous with the change in state of the external
TRIG signal from OFF to ON.
CONTINUE
Continuous measurement
Measurement is repeatedly performed for the duration that the TRIG signal is ON.

Selecting the teaching mode from an external device

There are two teaching modes from an external device.
MENU Mode-[SYS1]-[TEACH TYPE]
Setting
STATIONARY (default)
Teaching is performed with the workpiece in a stationary state. Input of the external
trigger input is required for teaching.
MOVING
The workpiece is moved when performing teaching.
Select this teaching mode only when the workpiece cannot be stopped.
Input of the external trigger is required for teaching.
Timing charts
p.34
Setting the System Environment
Description
Description
Description