Omron ZFV Series User Manual page 54

Smart sensors with ultra-high-speed ccd cameras
Hide thumbs Also See for ZFV Series:
Table of Contents

Advertisement

Item
WIDTH *
Select this item to detect width or interval.
Set the teaching area to the part of the workpiece to perform
measurement in, and execute teaching.
Example) To measure width
POSITION*
Select this item to detect the position of a workpiece.
Set the teaching area to the part of the workpiece to perform
measurement in, and execute teaching.
The edge of the workpiece is detected, and judgment is per-
formed by comparing those edge coordinates against refer-
ence coordinates.
Example)
COUNT*
Select this item when counting the number of workpieces.
Set the teaching area to the part of the workpiece to perform
detection in, and execute teaching. The edges in the teach-
ing area are detected, and judgment is performed by com-
paring the number of edges with a reference value.
Example) To detect the number of leads
Description
Set so that there are two changes in brightness in
the detection area such as "light to dark" or "dark
to light."
Teaching area
Set so that there is one change in brightness in
the detection area such as "light to dark" or "dark
to light."
A change in brightness such as "light to dark to
light" or "dark to light to dark" is counted as "1". In
the above example, the count is "4".
Section 3
Executing Teaching
Example of Application
Detection of lead width
on capacitors or other
electronic components
Detection of bent
leads
Detection of out-of-
position labels
Detection of out-of-
position labels
Detection of the num-
ber of leads
Count of the number
of cables
ZFV
User's Manual
51

Hide quick links: