Logging Level sets the severity level for event logging.
•
Logging Facility‐Type specifies the syslog facility to use for messages, (16 to 23) local 0 to
local 7.
The system allows you to limit the messages that are logged by specifying a minimum severity
level. Table
4‐4 lists the error message levels from the most severe (Emergency) to least severe
(Debug). The message levels that are logged include the specified minimum level up to the
Emergency level.
Table 4-4 Logging Level Descriptions
Error Level
Description
Emergency
Immediate action needed
Alerts
Immediate action needed
Critical
Critical conditions (such as, memory allocation, or free memory error - resource
exhausted)
Error
Error conditions (such as, invalid input, or default used)
Warning
Warning conditions (such as, return false, or unexpected return)
Notice
Normal but significant condition, such as cold start
Informational
Informational messages only
Debug
Debugging messages
Note: The access point error log can be viewed using the Event Logs window in the Status section
(refer to
"Using Web Management to View Event
displays the last 128 messages logged in chronological order, from the newest to the oldest. Log
messages are erased when the device is rebooted.
Logs" on page 4-108).The Event Logs window
RoamAbout RBT-4102 Wireless Access Point Configuration Guide 4-45
System Log