Page 3
Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made.
This product complies with the following: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, IEC 60950. El producto de Enterasys cumple con lo siguiente: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, IEC 60950. Dieses Produkt entspricht den folgenden Richtlinien: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, IEC 60950.
Page 5
This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. Caution: To comply with the FCC RF exposure compliance requirements, the following antenna installation and device operating configurations must be satisfied: For integral and external antenna configurations:...
Application of Council Directive(s): European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: Enterasys Networks, Inc. declares that the equipment packaged with this notice conforms to the above directives. Declaration of Conformity 89/336/EEC 73/23/EEC Manufacturer’s Name: Enterasys Networks, Inc. Manufacturer’s Address:...
Page 7
This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc. on behalf of itself and its Affiliates (as hereinafter defined) (“Enterasys”) that sets forth Your rights and obligations with respect to the Enterasys software program/firmware installed on the Enterasys product (including any accompanying documentation, hardware or media) (“Program”) in the package and prevails over any additional, conflicting or...
Page 8
52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Program is considered commercial computer software in accordance with DFARS section 227.7202-3 and its successors, and use, duplication, or disclosure by the Government is subject to restrictions set forth herein.
Page 9
Agreement shall be void and a breach of this Agreement. 12. WAIVER. A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in writing and will not be construed as a waiver of any subsequent breach of such term or condition. Enterasys’ failure to enforce a term upon Your breach of such term shall not be construed as a waiver of Your breach or prevent enforcement on any other occasion.
Preface Purpose of This Manual ... xi Intended Audience ... xi Associated Documents ... xi Document Conventions... xii Getting Help ... xii Chapter 1: Preparing for Installation Overview ...1-1 Reviewing the Site Requirements ...1-2 Hardware Requirements ...1-2 Environmental Requirements ...1-2 Power Supply and Connector Specifications (World) ...1-3 Regulatory Compliance ...1-4 Unpacking and Inspecting ...1-5...
Page 12
Chapter 3: Installing the RoamAbout R2 Overview ...3-1 Upgrading from an Existing Access Point 2000 ...3-2 Wall/Ceiling Outlet Box Installation ...3-3 Surface Wallmount Installation ...3-8 Console Port Connection ...3-14 Connecting a Device to the Console Port ...3-14 Connecting an Open-Ended Cable to the Console Port ...3-16 Verifying the Operation of the RoamAbout R2 ...3-17 Chapter 4: Configuring the RoamAbout R2 Overview ...4-1...
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion. Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden. Associated Documents You can download the documentation from the Enterasys Networks Web site. Documentation URL: Documentacion URL: Dokumentation: Check the Web site regularly for product upgrades: http://www.enterasys.com/products/wireless...
Document Conventions The following icons are used in this document: Getting Help For additional support related to this device or document, contact Enterasys Networks using one of the following methods. World Wide Web: Phone: Email: To send comments or suggestions concerning this document to the Technical Writing Department: techwriting@enterasys.com...
Page 15
• The serial and revision numbers of all involved Enterasys Networks products in the network • A description of your network environment (for example, layout and cable type.) • Network load and frame size at the time of trouble (if known) •...
Overview This chapter describes basic considerations for successfully installing the RoamAbout R2 hardware. Before installing the RoamAbout R2, you must complete the following tasks: If you have an existing Access Point 2000 and want to install the RoamAbout R2 in its place, refer to important information.
Reviewing the Site Requirements Please review the site requirements before you install the RoamAbout R2. Hardware Requirements The physical specifications for the RoamAbout R2 are provided in Table 1-1 RoamAbout R2 Physical Specifications (with security cover) Parameter Width Depth Length Weight Environmental Requirements Ensure that the environmental requirements are within the ranges described in...
If the remote power feature is used, you must test the Ethernet cable from the remote power injector to the RoamAbout R2 for continuity and correct pinout before power is applied. Enterasys assumes no responsibility if the specifications set forth as follows are not followed.
Table 1-3 RoamAbout R2 Power Supply Specifications (World) Parameter Power Connector Power Consumption 100 to 240 Vac Regulatory Compliance This equipment meets the following safety and electromagnetic compatibility (EMC) requirements: • Safety EC Directive 73/23/EEC (EN 60950) Europe, CSA C22.2 No. 950, AS/NZS 3200 Australia/New Zealand, IEC 950 (CB Scheme) International Countries, UL 1950 USA, TUV European certification, Return Air Plenum Rated UL2043 •...
Physically inspect all cartons for shipping damage. Report any damage to your shipping carrier. Also verify that you have received the correct basic components and options as listed on the following pages. Report any discrepancies to your Enterasys Sales Representative.
802.11b radio cards are no longer available. Refer to the RoamAbout 802.11a/b/g Radio Certification and Regulatory Information document available on the Enterasys Networks Web site: www.enterasys.com/products/wireless. Note: You must be running RoamAbout R2 Wireless Access Platform firmware Version 6.xx, or higher, to use the 802.11 a/b/g card. The RoamAbout AP Manager Kit 11.06, or higher, contains the latest firmware.
Options The options shown below are available for the RoamAbout R2 (contact your Enterasys Representative), and are described in Table 1-5 RoamAbout R2 Options Option Description RoamAbout R2 Mezzanine slot upgrade option for RBTR2-AA and RBTR2-AB (user interchangeable part replaces the original one-slot).
Testing the Coverage Area Enterasys Networks recommends that you test the coverage area before you permanently install the RoamAbout R2. The coverage area is where wireless clients can be physically located and still connect to the RoamAbout R2. Coverage area is determined by a number of factors, including the speed of the RoamAbout radio card, physical obstructions, and noise levels.
This chapter presents detailed step-by-step procedures to select, configure, and install the correct power, cabling, and wiring for your RoamAbout R2. Caution: The Enterasys 5652054-xx International DC Power Supply (ships with the RoamAbout R2) and the RBTR2-PS3 Redundant DC Power Supply have overload protection.
(el RoamAbout R2 o la toma en la pared) para asegurarse de que este cable no esté conectado a otro aparato. Enterasys offers an optional rack mount kit that allows installation of up to three remote power injectors into one standard rack-mount panel. Refer to Installation”...
Remote Power Injector Installation The remote power injector provides operating power to the RoamAbout R2 (referenced in the following figure as RoamAbout AP) using the Ethernet cable. The injector receives input power (via the PWR jack) from either the power supply supplied with the RoamAbout R2 or directly from the site facility.
Page 28
To install the remote power injector, perform the following steps: Use a cable tester to check the cable wiring to the RoamAbout R2. Check the continuity and pairing. Select a mounting location: – Close to the Ethernet wiring panel or Ethernet port. –...
Rack Mount Kit Installation The rack mount kit allows you to install up to three remote power injectors into one standard rack-mount panel, shown below, to provide for the operation of up to three RoamAbout R2s. The information presented in the to each of the three remote power injectors in the rack mount kit.
Power Supply Installation To install the 100-240 Vac power supply, perform the following steps: Verify that you have the correct power supply connector. Insert the appropriate connector into the power supply. Caution: Do not connect the power supply to the primary source until instructed to do Precaución: No conecte la fuente del poder a la fuente primaria hasta que no se le indique.
Ethernet Wiring Configuration The RoamAbout R2 supports the 100BaseT Ethernet cabling standard with auto negotiation. If you have an existing 10BaseT Ethernet cable in place, you can connect the cable directly to the RoamAbout R2. You can also connect the Ethernet cable to the remote power injector, then connect the remote power injector to the RoamAbout R2.
Air Space and Plenum Environments IMPORTANT: If you are planning to install the RoamAbout R2 in Air Space or in a Plenum environment, refer to the following caution. 2-8 Cabling and Wiring Caution: If you are installing the RoamAbout R2 in Air Space or a Plenum environment, the RoamAbout R2 must only be powered by the Remote Power Splice through a Plenum-rated CAT-5 cable.
RoamAbout R2. For a LAN-to-LAN configuration, also write down the MAC address on the back of the radio card, which is the wireless MAC address. Installing the RoamAbout R2 RoamAbout R2 Wireless Access Platform Hardware Installation Guide 3-1 www.enterasys.com/...
Upgrading from an Existing Access Point 2000 Caution: If you have an existing Access Point 2000 and want to install the RoamAbout R2 in its place, please refer to the following important information. Precaución: Si tiene instalado un Access Point 2000 y desea sustituirlo por un RoamAbout R2, tenga en cuenta la siguiente información.
Wall/Ceiling Outlet Box Installation Follow the step-by-step procedure below to install the RoamAbout R2 to an outlet box. Make sure the site primary power for the RoamAbout R2 conforms to the specifications detailed in Select a wall or ceiling outlet: •...
Page 36
Ensure that the mounting holes on the bracket line up with those on the outlet box. Additional holes may be drilled in the bracket to accommodate your particular installation. Note: Remove all drilled material from the area. Secure the mounting bracket to the wall outlet box. Secure the RoamAbout R2 to the mounting bracket: Insert the two RoamAbout R2 shoulder screws into the two mounting bracket screw slots until secure.
Page 37
Refer to the Regulatory information, FCC requirements, and installation information shipped with the radio card before you install it into the RoamAbout To install the radio card: Ensure that the power to the RoamAbout R2 is off. b. Carefully insert the card into the radio card slot. Press down firmly to seat the card.
Page 38
If you install the optional Dual Band Range Extender Antenna or the outdoor antenna: Remove the dust cover from the radio card connector. b. Insert the antenna cable connector into the radio card connector. Gently press down on the cable connector to secure the antenna connection.
Page 39
Wall/Ceiling Outlet Box Installation Push the cover down until all four snaps are secured. d. Lock the cover in place using the key. RoamAbout R2 Wireless Access Platform Hardware Installation Guide 3-7...
Surface Wallmount Installation Follow the step-by-step procedure below to install the RoamAbout R2 on the surface of a wall, cubical wall, vertical support structure, or ceiling. Make sure the site primary power for the RoamAbout R2 conforms to the specifications detailed in Select the optimum mounting location: •...
Page 41
Flatten the metal mounting bracket tab against the bracket, or remove the tab by bending it back and forth. Secure the mounting bracket to the wall: Locate at least two mounting holes/slots on the mounting bracket that line up with a wall stud. b.
Page 42
Secure the RoamAbout R2 to the mounting bracket: Insert the two RoamAbout R2 shoulder screws into the two mounting bracket screw slots. b. Slide the shoulder screws in the mounting screw slots until the screws are secure. Tighten the captive screw to secure the RoamAbout R2. 3-10 Installing the RoamAbout R2...
Page 43
Refer to the Regulatory information, FCC requirements, and installation information shipped with the radio card before you install it into the RoamAbout To install the radio card: Ensure that the power to the RoamAbout R2 is off. b. Carefully insert the card into the radio card slot. Press down firmly to seat the card.
Page 44
If you install the optional Dual Band Range Extender antenna or the outdoor antenna: Remove the dust cover from the radio card connector. b. Insert the antenna cable connector into the radio card connector. Gently press down on the cable connector to secure the antenna connection.
Page 45
12. Verify that the power is on by observing that some of the RoamAbout R2 LEDs are flashing or lit. 13. Secure the cover: Position the cover over the RoamAbout R2. b. Make sure the cover clears the antenna. Push the cover down until all four snaps are secured. d.
Console Port Connection You can manage the R2 using its console port, Telnet, SSH client, or the RoamAbout AP Manager. You do not need to use the console port if you use the RoamAbout AP Manager. If you use Telnet or SSH, you will need to connect to the console port to set up the R2 IP address before you can access the R2.
Page 47
Choose a name that identifies the connection type, such as RoamAbout R2 Console Port. Ignore or cancel any prompts for modem or phone information. d. In the Connect Using (or similar field), select the port that is connected to the RoamAbout R2, such as COM1.
Console Port Connection Connecting an Open-Ended Cable to the Console Port The R2 console port requires that the cable is connected to another device; otherwise, spurious noise could cause the R2 console port to be unresponsive especially when the R2 is reset.
Verifying the Operation of the RoamAbout R2 The RoamAbout R2 runs a series of self-tests on power-up and reports status using its LEDs. The diagnostics take several seconds to complete after power-up. describes the LEDs. If the RoamAbout R2 LEDs indicate an error, verify that you have correctly installed the RoamAbout R2.
Overview This chapter provides the basic procedures to configure the RoamAbout R2 for a wireless infrastructure network (where wireless clients access the LAN via the R2). Refer to the RoamAbout 802.11 Wireless Networking Guide to configure the R2 for a LAN-to-LAN network or for information on advanced configuration procedures, such as security settings.
Using the Console Port To connect a device to the console port, follow the instructions in Connection” • Use your arrow keys to navigate through the screens. • Press your Enter (or Return) key to activate a data entry field. •...
Page 53
11. Choose Wireless Configuration from the Main Menu, then choose Set/Show Wireless Configuration. 12. At the top of the screen, select the radio slot (1 or 2) to configure. 13. Enter the name of the wireless network. 14. Enter a channel. The channels vary, depending on country regulations. In a wireless client configuration (Workgroup bridge mode) with multiple APs, adjacent APs should be set to different channels that are at least five channels apart.
Using the RoamAbout AP Manager To manage the R2 using the AP Manager, you need the R2’s wired MAC address. At the computer with AP Manager installed, start the AP Manager by clicking the Start button on the desktop and selecting Programs → RoamAbout → AP Manager. Click on the Setup/Add New AP button to setup/add a RoamAbout R2.
Page 55
Enter a station name. The station name is displayed when clients run the RoamAbout Client Utility. Each RoamAbout R2 should have a unique station name. 10. Select File → Save from the main window to save the configuration changes to a .cfg file.
Page 56
Using the RoamAbout AP Manager 4-6 Configuring the RoamAbout R2...
This appendix describes how to upgrade the RoamAbout R2 firmware using the console port or AP Manager. It also describes how to reset the R2 to all factory defaults. Check the Enterasys Networks Wireless web site for the latest RoamAbout AP Manager and firmware. Go to Download Library to download the latest AP Manager and RoamAbout R2 firmware.
Precaución: La aplicación NetRider Loader sólo indica cuándo se ha acabado de copiar el archivo, no indica cuándo se ha acabado el proceso de actualización. Choose Reset/Upgrade from the Main menu. Choose Reset Switch. 10. Choose Save to reset the unit. A-2 RoamAbout R2 Wireless Access Platform Hardware Installation Guide...
Using the RoamAbout AP Manager Select the RoamAbout R2 that you want to upgrade from the RoamAbout AP Manager Managed List. Click the Reload button on the Main window. Select one of the following: • Use this Computer The firmware image is on the same computer and in the same directory as the AP Manager, which uses the NetRider Loader application to load the image.
Page 60
11. Click Yes in the Poll dialog box to start the poll. You will receive a “Reload Status = Success” message when the upgrade is complete. The upgrade takes approximately one minute. AP Manager prompts you to reset the unit after the upgrade is complete. 12.
Hardware Reset to Factory Defaults The RoamAbout R2 has a Reload/Reset button. This button is used to download a new firmware image to the RoamAbout R2, and to reset the RoamAbout R2 to the factory defaults. Please note the following before you reset the R2 to the factory defaults: •...
Page 62
NetRider Loader indicates a loading status. Caution: The NetRider Loader application only indicates when the file copy is completed, it does not indicate when the upgrade is complete. Precaución: La aplicación NetRider Loader sólo indica cuándo se ha acabado de copiar el archivo, no indica cuándo se ha acabado el proceso de actualización.
Need help?
Do you have a question about the RoamAbout AP-2000 and is the answer not in the manual?
Questions and answers