Example Of Event Counter Operation - HP PROCURVE 6120 Management And Configuration Manual

Procurve series 6120 switches
Table of Contents

Advertisement

Troubleshooting
Using the Event Log for Troubleshooting Switch Problems
C-36

Example of Event Counter Operation

Suppose the switch detects the following after a reboot:
Three duplicate instances of the PIM "Send error" during the first log
throttle period for this event
Five more instances of the same Send error during the second log throttle
period for this event
Four instances of the same Send error during the third log throttle period
for this event
In this case, the duplicate message would appear three times in the Event Log
(once for each log throttle period for the event being described), and the
Duplicate Message Counter would increment as shown in table C-4. (The same
operation would apply for messages sent to any configured SNMP trap
receivers.)
Table C-4.
How the Duplicate Message Counter Increments
Instances
Instances
During 1st Log
During 2nd Log
Throttle Period
Throttle Period
3
*This value always comprises the first instance of the duplicate
message in the current log throttle period plus all previous occurrences
of the duplicate message occurring since the switch last rebooted.
Instances
During 3rd Log
Throttle Period
5
4
Duplicate
Message
Counter*
1
4
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 6120g/xgProcurve 6120xg

Table of Contents