NEC Express5800/140Rf-4 User Manual page 305

Table of Contents

Advertisement

On-screen message
IO +3.3V AUX Alm 07
IO +3.3V AUX Alm 00
IO +1.8Vs Alm 07
IO +1.8Vs Alm 00
IO +1.2Vs Alm 07
IO +1.2Vs Alm 00
IO +1.0Vs Alm 07
IO +1.0Vs Alm 00
IO +12V Alm 07
IO +12V Alm 00
IO +5V Alm 07
IO +5V Alm 00
IO +3.3V Alm 07
IO +3.3V Alm 00
IO +1.5V Alm 07
IO +1.5V Alm 00
IO +1.0V Alm 07
IO +1.0V Alm 00
Battery Alm 07
Battery Alm 00
FP Temp Alm 07
FP Temp Alm 00
BB Temp Alm 07
BB Temp Alm 00
SASBP Temp NCAlm
Description
Recommended action
+3.3V AUX voltage warning (upper limit) occurred in I/O riser board.
+3.3V AUX voltage warning (lower limit) occurred in I/O riser board.
+1.8Vs voltage warning (upper limit) occurred in I/O riser board.
+1.8Vs voltage warning (lower limit) occurred in I/O riser board.
+1.2Vs voltage warning (upper limit) occurred in I/O riser board.
+1.2Vs voltage warning (lower limit) occurred in I/O riser board.
+1.0Vs voltage warning (upper limit) occurred in I/O riser board.
+1.0Vs voltage warning (lower limit) occurred in I/O riser board.
+12V voltage warning (upper limit) occurred in I/O riser board.
+12V voltage warning (lower limit) occurred in I/O riser board.
+5V voltage warning (upper limit) occurred in I/O riser board.
+5V voltage warning (lower limit) occurred in I/O riser board.
+3.3V voltage warning (upper limit) occurred in I/O riser board.
+3.3V voltage warning (lower limit) occurred in I/O riser board.
+1.5V voltage warning (upper limit) occurred in I/O riser board.
+1.5V voltage warning (lower limit) occurred in I/O riser board.
+1.0V voltage warning (upper limit) occurred in I/O riser board.
+1.0V voltage warning (lower limit) occurred in I/O riser board.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power
cord. Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the I/O riser board.
If the same error persists, contact your service representative.
Voltage warning (upper limit) occurred on lithium battery.
Voltage warning (lower limit) occurred on lithium battery.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power
cord. Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the lithium battery on base board.
If the same error persists, contact your service representative.
A high temperature warning occurred in front panel.
A low temperature warning occurred in front panel.
A high temperature warning occurred in base board.
A low temperature warning occurred in base board.
Check if fans in the server work normally.
If the same error persists, contact your service representative.
A temperature warning occurred in SAS riser board.
Troubleshooting 8-41