Error
Error message
code
82E0
DIMM #1 with error is enabled
82E1
DIMM #2 with error is enabled
82E2
DIMM #3 with error is enabled
82E3
DIMM #4 with error is enabled
82E4
DIMM #5 with error is enabled
82E5
DIMM #6 with error is enabled
82E6
DIMM #7 with error is enabled
82E7
DIMM #8 with error is enabled
82E8
DIMM #9 with error is enabled
82E9
DIMM #10 with error is enabled
82EA
DIMM #11 with error is enabled
82EB
DIMM #12 with error is enabled
82EC
DIMM #13 with error is enabled
82ED
DIMM #14 with error is enabled
82EE
DIMM #15 with error is enabled
82EF
DIMM #16 with error is enabled
82F0
DIMM #17 with error is enabled
82F1
DIMM #18 with error is enabled
82F2
DIMM #19 with error is enabled
82F3
DIMM #20 with error is enabled
82F4
DIMM #21 with error is enabled
82F5
DIMM #22 with error is enabled
82F6
DIMM #23 with error is enabled
82F7
DIMM #24 with error is enabled
82F8
DIMM #25 with error is enabled
82F9
DIMM #26 with error is enabled
82FA
DIMM #27 with error is enabled
82FB
DIMM #28 with error is enabled
82FC
DIMM #29 with error is enabled
82FD
DIMM #30 with error is enabled
82FE
DIMM #31 with error is enabled
82FF
DIMM #32 with error is enabled
8700
Mismatch BMC PIA detected.
[200V Non-Redundant]
8701
Mismatch BMC PIA detected.
[100V Redundant / 100V Non-Redundant]
Mismatch BMC PIA detected.
8702
[100V Non-Redundant]
Troubleshooting 8-23
Recommended Action
DIMM numbers shown in error message are
as show below.
DIMM #1 to DIMM #8:
DIMM #1 to DIMM #8 on memory board A
DIMM #9 to DIMM #16:
DIMM #1 to DIMM #8 on memory board B
DIMM #17 to DIMM #24:
DIMM #1 to DIMM #8 on memory board C
DIMM #25 to DIMM #32:
DIMM #1 to DIMM #8 on memory board D
1. Run BIOS SETUP, select [Advanced] -
[Memory Configuration] - [Memory Retest]
- [Yes], then select [Exit] - [Exit Saving
Changes].
2. Check installation status of failed DIMM.
3. Replace the failed DIMM.
4. Replace the relevant memory board.
5. If the same error persists, contact your
service representative.
Note: The detailed error information can be
obtained by viewing the IPMI system
event log.
If the processor is replaced, restart the
server and run BIOS SETUP. Select
[Main] - [Processor Settings] -
[Processor Retest] - [Yes], then select
[Exit] - [Exit Saving Changes].
1. Apply PIA appropriate to AC input voltage
and device configuration.
The server is configured to use 100 VAC
non-redundant power supply unit. If you
changed configuration, update PIA (see
"Power Supplies" in Chapter 2).
2. If the same error persists, contact your
service representative.