When STATUS lamp is flashing in green
On-screen
message
CPU Reconfigured
Mem Reconfigured
Mem(xx) D(y) Unc
Err
Mem(x) DIMM(y) C
Err
PCI Slot(x) C Err
Description
Recommended action
The system has started with processor degraded.
Try the following steps to cancel the error.
Run BIOS SETUP, select [Main] - [Processor Settings] - [Processor Retest]-
[Yes], then select [Exit] - [Exit Saving Changes].
If the same error persists, contact your service representative.
The system has started with memory degraded.
Try the following steps to cancel the error.
Run BIOS SETUP, select [Advanced] - [Memory Configuration] - [Memory
Retest]- [Yes], then select [Exit] - [Exit Saving Changes].
If the same error persists, contact your service representative.
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM in the following location (in memory mirroring configuration).
(xx): Memory board that contains the failed DIMM.
AB: Memory board A or B
CD: Memory board C or D
(y):
Slot number of the memory board that contains the failed DIMM.
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed DIMMs.
3. Replace the failed DIMMs.
If the same error persists, contact your service representative.
A correctable error occurred on DIMM in the following location.
(x):
Memory board that contains the failed DIMM.
A: Memory board A
B: Memory board B
C: Memory board C
D: Memory board D
(y):
Slot number of the memory board that contains the failed DIMM.
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed DIMMs.
3. Replace the failed DIMMs.
If the same error persists, contact your service representative.
A correctable error occurred on PCI card installed in PCI slot (x).
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed PCI card.
3. Replace the failed PCI card.
If the same error persists, contact your service representative.