8-36 Troubleshooting
On-screen
message
Proc1 Config Err
Proc2 Config Err
Proc3 Config Err
Proc4 Config Err
Proc1 Didn't Start
Proc2 Didn't Start
Proc3 Didn't Start
Proc4 Didn't Start
WDT Power Down
WDT Power Cycle
WDT Timeout
Description
Recommended action
The processor installed in the processor #1 slot is unsupported, failed, or its
combination is illegal.
The processor installed in the processor #2 slot is unsupported, failed, or its
combination is illegal.
The processor installed in the processor #3 slot is unsupported, failed, or its
combination is illegal.
The processor installed in the processor #4 slot is unsupported, failed, or its
combination is illegal.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the failed processor.
4. Replace the failed processor.
If the same error persists, contact your service representative.
Failed to start processor #1.
Failed to start processor #2.
Failed to start processor #3.
Failed to start processor #4.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the failed processor.
4. Replace the failed processor.
If the same error persists, contact your service representative.
The system is forcedly shutdown due to watchdog timer timeout error.
Turn on the power of the server.
If the same error persists, contact your service representative.
The system is rebooted due to watchdog timer timeout error.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Watchdog timer timeout error occurred.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.