NEC Express5800/140Rf-4 User Manual page 281

Table of Contents

Advertisement

Error
Error message
code
The error occurred during temperature sensor
0B70
reading.
0B71
System Temperature out of the range.
0B74
The error occurred during voltage sensor
reading.
0B75
System voltage out of the range.
0B78
The error occurred during fan sensor reading
The error occurred during redundant power
0B7C
module confirmation
0B7D
The normal operation can't be guaranteed
with use of only one PSU
0B7E
Mismatch AC Voltage detected.
0B7F
Insufficient Power Supply Unit Configuration
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A
BMC SEL area full.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted.
0B93
BMC SDR Repository empty.
Troubleshooting 8-17
Recommended Action
Contact your service representative.
A fan failure or fan clogging may occur.
Contact your service representative to
request the maintenance.
Contact your service representative.
Contact you service representative to
replace the power supply unit.
Contact you service representative to add
an additional power supply unit or replace
the existing power supply unit.
Check if the same voltage (100 or 200 VAC)
is input to power supply units.
Check installation status of power supply
units.
If the error cannot be corrected, contact
your service representative.
Check installation status of power supply
units.
If the error cannot be corrected, contact
your service representative.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
All the commands and functions other than
the FRU command and the EMP function
can be used. This is not a fatal error. Turn
off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.
Turn off the power once and then on again
to restart the server. If the error cannot be
corrected, contact your service
representative.