On-screen message
Mem A Temp Alm 09
Mem A Temp Alm 02
Mem B Temp Alm 09
Mem B Temp Alm 02
Mem C Temp Alm 09
Mem C Temp Alm 02
Mem D Temp Alm 09
Mem D Temp Alm 02
PS1 Temp Alm 09
PS1 Temp Alm 02
PS2 Temp Alm 09
PS2 Temp Alm 02
Proc1 Therm % 09
Proc1 Therm % 02
Proc2 Therm % 09
Proc2 Therm % 02
Proc3 Therm % 09
Proc3 Therm % 02
Proc4 Therm % 09
Proc4 Therm % 02
AC lost Alm 1
AC lost Alm 2
Description
Recommended action
A high temperature alarm occurred in memory board A.
A low temperature alarm occurred in memory board A.
A high temperature alarm occurred in memory board B.
A low temperature alarm occurred in memory board B.
A high temperature alarm occurred in memory board C.
A low temperature alarm occurred in memory board C.
A high temperature alarm occurred in memory board D.
A low temperature alarm occurred in memory board D.
1. Check if fans in the server work normally.
2. Check installation status of the failed memory board.
If the same error persists, contact your service representative.
A high temperature alarm occurred in power supply unit #1.
A low temperature alarm occurred in power supply unit #1.
A high temperature alarm occurred in power supply unit #2.
A low temperature alarm occurred in power supply unit #2.
1. Check if fans in the power supply unit work normally.
2. Check if fans in the server work normally.
3. Check installation status of the failed power supply unit.
If the same error persists, contact your service representative.
A high temperature alarm occurred in processor #1.
A low temperature alarm occurred in processor #1.
A high temperature alarm occurred in processor #2.
A low temperature alarm occurred in processor #2.
A high temperature alarm occurred in processor #3.
A low temperature alarm occurred in processor #3.
A high temperature alarm occurred in processor #4.
A low temperature alarm occurred in processor #4.
1. Check if fans in the server work normally.
2. Check installation status of the failed processor and processor heat
sink.
If the same error persists, contact your service representative.
The power supply unit #1 failed to supply AC power.
The power supply unit #2 failed to supply AC power.
1. Check connection status of AC power cord of failed power supply unit.
2. Turn off the DC power of the server, and disconnect the AC power
cord. Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Troubleshooting 8-39