7.1.9 Color Temperature
White Default CCT (without YNF)
White YNF CCT (with YNF activation, electronically
corrected)
Range of Adjustment
Tracking (deviation from normal over full range from 10
to 100 IRE)
Stability (during rated lamp life)
7.1.10Convergence
Convergence zones A, B, C are as defined in Figure 2. Zone A has a diameter ¼ of the image height. Zone B
has a diameter of full image height. All specified convergence errors are between any two colors after a
minimum warm-up of 30 minutes.
Convergence is specified with a 1.4-1.8 HD lens (part number 118-100112-01) in the 1.4:1 position with zero
offset. Bore-sight alignment must be adjusted for zero angular error. (Note: convergence error includes the
effects of lateral color in the projection lens. Measurements must be done on horizontal and vertical test pattern
lines that intersect the center of the image).
(Figure applicable to both 1080p and SXGA+)
MEASUREMENT AREA
Zone A
Zone B
Zone C
M Series User Manual
020-100009-08 Rev. 1 (05-2013)
7700 K ±2000 K 350W, 450W Lamp
8900 K ±2000 K 200W Lamp
6500 K ±1000 K
3200 K - 9300 K
±500 K max
±500 K max
MAXIMUM CONVERGENCE ERROR (PIX-
ELS)
1/4
1/2
3/4
Section 7: Specifications
7-3