3. Use the same lamp mode for all projectors, and do the following:
• Set Select Color Adjustment to Max Drives
• Display a full white test pattern
• Adjust lamp power and Optical Aperture until adjacent white fields appear the same brightness.
• Display the Color Adjustments by X,Y menus for all projectors. Each menu shows the x/y coordinates
defining the "Max Drives" color gamut for this projector.
NOTE: The values shown in one (any) of the displays. Use the "Copy From" function to copy them into
a "User" gamut in one projector.
4. In each projector, select a "User" color adjustment (1-4) to enable Color Adjustments by X,Y changes. Then
enter your recorded x/y values into each menu.
M Series User Manual
020-100009-08 Rev. 1 (05-2013)
Section 3: Operation
3-57