EPSON Stylus Pro 7000

FATAL ERRORS

Fatal error messages appear on the LCD panel to warn users that an
unrecoverable error has occurred. However, in some cases the printer may
recover if turned off and back on.
Table 3-23. Fatal Error
Item
LCD
Service Call nnnnnnnn
message
LED indicator
All LED indicators flash.
status
A fatal error occurs for one of the following reasons.
1) A problem occurred that the user cannot solve by himself.
2) A maintenance part has exceeded its useful life and if not
Details
replaced may cause damage to the printer or printer parts.
3) An illegal function was attempted or illegal command received
and the operation is impossible.
Turn off the printer and turn it back on. If the error does not
recur, continue normal operation.
Recovery
If the same fatal error occurs when you turn the printer back on,
see the following table and perform the necessary service.
Table 3-24. Fatal Error Code List
Code
00000100
Waste ink pads are full
00000101
Ink tubes have reached their predetermined
00010000
PF motor/ encoder check error (out of step error)
00010001
PF motor/motor out of step
00010002
PF motor/overcurrent
00010003
PF motor/ in position time-out error
00010004
CR motor/ encoder check error (out of step error)
Troubleshooting
Description
Description
Troubleshooting Using the Error Messages
Table 3-24. Fatal Error Code List (continued)
Code
00010005
CR motor/motor out of step
00010006
CR motor/overcurrent
00010007
CR motor/ in position time-out error
00010008
Servo watchdog time-out error
00010009
System watchdog time-out error
0001000A
CR home position sensor error
0001000B
PF home position sensor error
0001000C
Head slide (PG) home position sensor error
0001000D
Cover open sensor error (00)
0001000E
Cover open sensor error (01)
0001000F
CR motor/PWM output malfunction
00010010
PF motor/PWM output malfunction
00020000
NVRAM error
00020001
Internal RAM check error
00020002
SRAM check error
00020003
DRAM check error
Refer to
0002000B
Mail box error (memory error)
page
10020004
CPU vector 4 general illegal instruction
93
10020006
CPU vector 6 slot illegal instruction
93
10020009
CPU vector 9 CPU address error
93
1002000A
CPU vector 10 DMAC/DTC address error
94
1002000B
CPU vector 11 watchdog time-out error
94
100200**
CPU vector 32~63 (incorrect trapping)
94
95
Revision B
Description
Refer to
page
95
96
96
96
97
97
97
97
97
97
97
97
98
98
98
98
98
98
98
98
98
98
98
92