Print Menu; Parameter Menu; Initialize" Items; Update" Items - Epson Stylus PRO 7000 Service Manual

Color large format inkjet printer
Hide thumbs Also See for Stylus PRO 7000:
Table of Contents

Advertisement

EPSON Stylus Pro 7000

5.4.4 Print Menu

The Print menu performs the same test-printing functions as the "Test Print"
option on the Adjustment menu. For details, see "Test Pattern Print" on
page 192.

5.4.5 Parameter Menu

Using this menu you can reset or change the parameters for the printer
mechanism controls. However, the parameters on this menu can also be
modified from the Adjust menu. When servicing the printer, you do not need
to separately update or reset the parameters from this menu.
[Pause] to return to previous menu
[SelecType]
Parameter: Init.
Parameter: Update
[Item]
Figure 5-42. Parameter Menu Options

"INITIALIZE" ITEMS

The items you can reset (re-initialize) using this menu are described below.
Capping Position (see
"Adj Cap Position" on page 176)
Paper Feed Distance (see "Feed Adjustment" on page 189)
Serial No. (see "Test Pattern Print" on page 192 for more information)
Maintenance Record (see Table 5-9, "Maintenance Record Items," on
page 173)
Adjustment

"UPDATE" ITEMS

The items you can update are described below.
Capping Position (see
Head Rank voltage (see "Adj Input Rank" on page 177)
Print Position Items (Bi-D Adjustment/Gap Adjustment)
[Enter]
Paper Feed Distance (see "Feed Adjustment" on page 189)
Other
Mechanism Parameters (see the next page)
menus
Ink Parameters (see the following)
[Pause]
Self-Diagnostic Mode Menus
The parameters will update and be stored in the Flash memory
on the Main Board the next time the printer is turned off.
"Adj Cap Position" on page 176)
Revision B
195

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents