Table 2-19 Maintenance Switch (Sw4) Settings Of Pri/23 Card; Table 2-20 Dip Switch (Sw1) Settings Of Pri/23 Card; Figure 2-22 Pri/23 Card - Panasonic DBS 576 Technical Manual

Section 300 installation
Hide thumbs Also See for DBS 576:
Table of Contents

Advertisement

Section 300-Installation
Figure 2-22. PRI/23 card
Tables 2-14 to 2-17 show the switch settings and LED indications.
Table 2-19. Maintenance switch (SW4) settings of PRI/23 card
Setting
Description
ON
Card is in closed status, and can be mounted and removed when power is ON. (Send-
ing/receiving of calls is disabled. If this is set during speech, sending/receiving of
calls is disabled after speech ends.)
OFF
Normal operation (This switch is set to OFF for normal operation.)
Table 2-20. Dip switch (SW1) settings of PRI/23 card
Switch No.
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
SW1-6
SW1-7
SW1-8
576-13-300
Distance from the DBS 576 to the CSU
0 to 150 ft.
ON
OFF
OFF
OFF
OFF
OFF
OFF
DBS 576 (USA), issued 6/2/98
Chapter 2. System Overview
150-450 ft.
OFF
ON
OFF
ON
OFF
ON
OFF
Not used
450-655 ft.
OFF
OFF
ON
OFF
ON
OFF
ON
2-31