Section 300-Installation
EM24
Guidelines
• The EM24 (VB-44310) provides 24 flexible function (FF) keys. It can be attached
• The EM24 comes with a mounting bracket, screws, and a two-conductor cable for
• Locate the EM24 within 400 ft. (120m) of the cabinet. The maximum loop circuit
Installation
1. Attach the EM24 to the key phone using the mounting plate and the four screws,
2. Connect the EM24 to the key phone using the two-conductor cable.
3. Connect the EM24 to the secondary socket using a four-conductor cable.
Figure 6-19. EM24 connection
576-13-300
to any key phone.
connecting it to the key phone.
resistance to a EM24 is 20 Ohms.
as shown in Figure 6-19.
DBS 576 (USA), issued 6/2/98
Chapter 6. Peripheral Equipment
6-21