Fault Tracing; Rcna-01 Status Codes - ABB RCNA-01 User Manual

Rcna-01 controlnet adapter module
Table of Contents

Advertisement

Fault tracing

RCNA-01 status codes

The status of the ControlNet module is indicated by a 'fieldbus
status' parameter in the drive application program (refer to the
drive documentation).
IDLE
The drive could not initiate communication with the ControlNet
Module.
EXECUT. INIT
The module is initialising and performing self-test.
TIME-OUT
The ControlNet Module has stopped communicating with the
drive.
CONFIG ERROR
The ControlNet Module has not accepted the configuration file
downloaded from the drive. Check compatibility of module and
drive file version number.
OFF-LINE
The module has completed its power-up sequence, and is waiting
for a ControlNet Scanner or the Manager software to establish a
connection.
ON-LINE
The ControlNet module is connected and communicating with a
ControlNet Scanner or Manager software.
RESET
The drive has initiated a reset command to the module.
61
Fault tracing