50
Services Supported
Service Code No.
0x05
0x0E
0x10
Instance 0x01, Attributes
ID# Attribute
name
1)
0x03 Run 1
2)
0x04 Run 2
0x05 Net Control
0x06 State
0x07 Running 1
0x08 Running 2
0x09 Ready
0x0A Faulted
0x0B Warning
0x0C FaultRst
0x0D Fault Code
0x0F CtlFromNet
0x11 Force Fault
0x12 Force Status
Communication
Services Description
Get, Set 0 = Stop, 1 = Run
Get, Set 0 = Stop, 1 = Run
2)
Get, Set 0 = Local Control, 1 = Network Control
Get
1 = Start/up, 2 = Not_ready, 3 = Ready,
4 = Enabled, 5 = Stopping, 6 = FaultStop,
7 = Faulted
3)
Get
0 = Stopped, 1 = Running
4)
Get
0 = Stopped, 1 = Running
Get
1 = Ready, Enabled or Stopping
0 = Other state
Get
0 = Not faulted, 1 = Fault occurred
Get
0 = No Warnings present, 1 = Warning
Get, Set 0
Get
The fault that caused the last transition to
the Faulted state.
Get
0 = NetControl disabled
1 = NetControl enabled
Get, Set 0
Get
0 = Not Forced
Non-zero = Forced
Service Name
Reset
Get Attribute Single
Set Attribute Single
1 Fault Reset
1 Force a fault
Data
type
BOOL
BOOL
BOOL
UINT8
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
UINT16
BOOL
BOOL
BOOL

Advertisement