Required Equipment

 ProxLink Radio Module
 PC with RS-232 Port running a terminal emulation software package. (Located: Start Button, Programs,
Accessories, then click on Hyper Terminal)
 ProxLink DB-9 to DB-25 Female RS-232 Cable
 9 VDC Power Supply
Configure
Select one of seven radio channels (902 - 928MHz). Make certain that the one chosen is set the same in all the
ProxLink located at the Transponders and for the ProxLink at the Central Console Computer.
Select one ProxLink for your Central Control Computer. The Serial # (located on a silver tag on the bottom of the
ProxLink) on this ProxLink must be entered in the Destination Serial Number and Serial # Filter location in all
ProxLink Radios connected to the Transponders.
1.
Attach the PC to the ProxLink using the ProxLink RS-232 cable. Attach the DB-9 Connector to the ProxLink
and attach the DB-25 Female Connector the PC. Gender changers or DB-25 to DB-9 converters may be
required depending on your serial port connector type.
2.
Start your terminal emulation software (Hyper Terminal). Configure the ProxLink as follows: 9600 Baud, 8
Data Bits, 1 Stop Bit and no parity.
3.
Put the ProxLink in User Interface mode by pressing the configuration button on the front of the unit. The
ProxLink should respond by displaying the Main Menu screen.
4.
Once the main menu is displayed, to configure a ProxLink parameter select a menu option and press the
[ENTER] key. This will either display a prompt or a sub-menu. After finishing with a sub-menu, press the
[ESC] key to return to the previous menu.
After you have finished configuring the ProxLink, type "L" and then [ENTER] and then type "Y" to place the
5.
unit in operating mode.
Configuration should look as follows in Main Menu, D - Display ProxLink Radio Module Parameters:
PARAMETER SETTINGS
Serial #______ ProxLink Radio to Transponders
Serial Port
----------
Operating Mode: Pass-Through
Echo Mode: None
Baud Rate: 9600
XON/XOFF Generation: Disabled
CTS Generation: Disabled
Network
------
Radio Channel: 6
Subchannel: 1
Dest. Serial #: 36591
Serial # Filter: 36591
Press <Enter> to continue. . .
PARAMETER SETTINGS
Serial # 36591 ProxLink Radio to Computer
Serial Port
--------
Operating Mode: Pass-Through
Echo Mode: None
Baud Rate: 9600
XON/XOFF Generation: Disabled
CTS Generation: Disabled
Network
------
Radio Channel: 6
Subchannel: 1
Dest. Serial #: Broadcast
Serial # Filter: None
Press <Enter> to continue. . .
ProxLink Radio Module Configuration
Security Escort Training
Page 41 of 142
Delimiters: None
Max Length: 256
Input Time-Out: 1
XON/XOFF Recognition: Disabled
DSR Generation: Disabled
Radio Speed: 121 Kbaud
Broadcast Address: 1
Lost Communication: Continue
Type Filter: Broadcast
These numbers must match
Delimiters: None
Max Length: 256
Input Time-Out: 1
XON/XOFF Recognition: Disabled
DSR Generation: Disabled
Radio Speed: 121 Kbaud
Broadcast Address: 1
Lost Communication: Continue