Phone Number - Bosch SE2005 Installation, Operating And Maintenance Manual

Security escort system
Hide thumbs Also See for SE2005:
Table of Contents

Advertisement

Pager Setup Dialog
This dialog sets up remote pager
access for troubles (service) and
alarms (security).
Automatically Send Selected
Troubles
If checked send the troubles
selected in the Popup Trouble
Filter dialog to the service pager.

Phone Number

Phone number to be dialed to
access the paging service. This
phone number is usually different
from the number you would
manually dial to send a page.
The paging company assigns this
value.
Password
Pager ID
Character Limit
Pages Per Call
Pager Group
Baud Rate
System Name
System Phone
Send Installer Demo
Alarms
Send All Other
Alarms
This is the password that must be sent to the paging service to send the page. If not
required, leave this field black. Usually a password is not required. The paging company
assigns this value.
This is the ID that identifies the specific pager that this message is to be sent to. Many
times it is the last 7 digits of the phone number that you would manually dial to access this
pager. The paging company assigns this value.
This is the maximum number of characters that are allowed per page. Typically this is set
to 80 characters. The Security Escort System will truncate the pager message at this
number of characters. The paging company assigns this value.
This is the maximum number of pager messages that are allowed per phone call.
Typically this is set to 4 pages per call. When this number of messages have been sent
and there are more messages to be delivered; the Security Escort System will hang up
and redial the paging service to deliver the remaining messages. The paging company
assigns this value.
This is the group of up to 8 pagers that this message is to be sent to. You may program
the individual pager as well as a group of pagers. The pager group will be sent the page
before the individual.
This is the baud rate that will be used to communicate with the paging computers. The
paging company assigns this value.
This will identify the Security Escort System when multiple Security Escort Systems report
to the same service pager. Keep this field as short as reasonably possible since these
characters plus a space will be sent before each trouble message and they are included
in the "Character Limit" set above. If not desired, leave blank.
This will present phone number to be called to respond to the service page. Only use if
required since these characters plus a space will be sent before each trouble message
and they are included with the "System Name" in the "Character Limit" set above. If not
desired, leave blank.
If checked demo alarms will be sent to the security pager.
If checked all actual alarms will be sent to the security pager.
Security Escort Training
Page 130 of 142
Pager Setup Dialog

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se2010Se2050Se2100

Table of Contents