EA500 Transponder
General
The EA500 Transponder is the Security Escort module that provides communications between the Central
Console and the many Receivers and Alert Units throughout the protected area. In addition to its
communications functions, it also supplies power to the Receivers. Each Transponder also includes drivers for a
single strobe and siren.

Specifications

Enclosure (AE3):
Hardware Kit:
Temperature Range:
Power:
Power Output:
Driver Outputs:
Battery Backup:
Multiplex Buses:
Comm. Interface:
Keyswitch Input:
Compatibility:
Mounting
Normally, the enclosures are mounted first and all the wiring run, then the electronics are mounted, wired, and
tested.
The enclosures come with their own mounting hardware (H500 Hardware Kit) for mounting the enclosure to a
wall and mounting the circuit board to the enclosure.
Mount the enclosure to the mounting surface.
Mount the circuit board to the enclosure.
Wiring
Wire the transponder. See Figure 3.
Wiring to Receivers and Alert Units can be Home-Run (individual), Daisy-Chain (from device to device), or a
combination of both. T-Tapping is OK. The recommended cable is 4-conductor, 18 AWG (1.2mm) fire rated.
Wiring from SE485 to Transponders can be Home-Run (individual), Daisy-Chain (from device to device), or a
combination of both. T-Tapping is OK. The recommended cable is 4-conductor, 22 AWG (0.8mm).
Set the Address
Every Transponder in the system must have its own address. Set the address on the transponder using the
dipswitches in the upper-right corner. See the Figure 2.
Figure 4 shows how to set the dip switches for each possible address.
15 in. W, 20.75 in. H, 4.25 in. D
H500
-40° to +149°F (-40° to +65°C)
18.0 VAC, 50 VA maximum plug-in Transformer for 110 V, 60 Hz
Supplies battery backed 12.0 VDC power to Receivers
9V DC used for SE485 or for Proxim radio power
Strobe: 500 mA solid state sink, terminal switches to ground in an alarm condition.
Siren: 500 mA solid state sink, terminal switches to ground in an alarm condition.
12 VDC Lead Acid Battery
8 multiplex drivers, each capable of driving 8 Receivers or Alert Units for a combined total of
64 Receivers and Alert Units per transponder
Selectable SE485 or RS-232
47k EOL resistor, supervised loop
*ROM version 4.00 or greater (version shipped with this unit) is compatible with "-304"
equipment (e.g., EA102A-304). Version 4.00 or greater is NOT compatible with non "-304"
equipment.
*ROM versions earlier than 4.00 are compatible with non "-304" equipment.