Connection Diagram

The optional CM444B relay module
provides an easy way to interface the
keypad's lock output to the door lock.
Because of its small physical size
(12.5 x 46 x 12mm) it can be easily lo-
cated in the wall cavity if required.
CM720B or CM723B
Power Supply
(Battery backed up)
DOOR
LOCK
+
PROTECTION
DIODE
Wiring Legend
RED
= LAN +
BLACK
= LAN -
WHITE
= LAN A
BLUE
= LAN B
YELLOW
= LOCK
GREEN
= EGRESS
You must power cycle the panel or perform
i
a LAN scan after connecting new keypads
Note
for the system to initialise the them.

Specifications

Part Numbers:
Operating Voltage:
Module Connection:
(RS485 LAN)
Lock Output:
Egress Input:
Dimensions:
Environment:
Fixing Method:
Warranty:
N12138
N12138
Bosch Security Systems
03/16 Graphic Keypads BIRG FTR1.0
The connection diagram shown below
includes the lock and egress functions
which are provided on the Smart Card
ONLY USE THE SUPPLIED CONNECTION
CABLE WHEN INSTALLING THE KEYPAD
CM444B RELAY CARD
CM444 Relay Card
N/O
COM
DF70
N/C
TO
DOOR
LOCK
BL
WH
BK
RD
EGRESS
INPUT
CP700B - CP710B- CP722B - CP723B - CP741B Graphic Keypads.
10.0V D.C. - 14.5V D.C. @ 100mA Max.
Max total LAN length using multi strand security cable = 500m,
Max total LAN length using 2 pair twisted shielded data cable (Belden 8723) = 1200m.
See full control panel manual for complete wiring instructions.
Protected open collector transistor output 500mA.
Low to trigger. Can be disabled via software control.
92mm(W), 20mm(D), 132mm(H). CM444B = 46mm(W), 12.5mm(D), 12mm H)
-30˚ to 55˚C RH 5 to 85% at 30˚C non-condensing.
Keypads should be mounted on a sturdy vertical wall using fixtures appropriate for the wall con-
struction type. See instructions for correct tamper installation.
3 years from date of manufacture (return to base).
In the interest of ongoing product development this
RoHS
document is subject to change without notice.
Graphic Keypads
enabled keypads only.
+12V
YL
Lock
Output
GN
Egress
Input
N/O
The egress input
is low (0V) to trigger.
Disable via panel
programming if not
being used.
Figure 9: Keypad Connection Diagram
Installer Reference Guide
Address Select Switch. Keypads must be
set to a unique address as per "DIP Switch
Address Settings" on page 3.
All Wi-Fi enabled keypads are supplied
from the factory set to Address 1.
ADDRESS
SW
1 2 3 4
1
X
2
X
3
X X
4
X
5
6
X
X
X X
7
8
X X X
X
9
ADDRESS
X
X
10
ON
X
X
11
X
X X
12
13
X X
1 2 3 4 5
X
X X
14
SW5 = LAN TERM
15
X X X
X X X X
16
Keypad tamper
If required switch
switch must be
number 5 (SW5) can be
installed correctly
turned ON to terminate
to provide front
the LAN at the keypad.
and rear tamper
See panel wiring
protection.
guidelines.
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp710bCp722bCp732bCp741bCp799b

Table of Contents