Status And Error Messages - Keithley 2002 User Manual

Hide thumbs Also See for 2002:
Table of Contents

Advertisement

Front Panel Operation
Table 2-4

Status and error messages

Number
Description
+900
"Internal System Error"
+611
"Questionable Temperature"
+610
"Questionable Calibration"
+519
"Excessive temp drift during cal"
+518
"Low level calibration data lost"
+517
"Preamp calibration data lost"
+516
"Install option id lost"
+515
"Calibration dates lost"
+514
"DC calibration data lost"
+513
"AC calibration data lost"
+512
"Power-on state lost"
+511
"GPIB address lost"
+510
"Reading buffer data lost"
+444 to
Calibration Errors
+350
(see Calibration Manual)
+312
"Buffer pretriggered"
+311
"Buffer lost"
+310
"Buffer full"
+309
"Buffer half full"
+308
"Buffer Available"
+307
"Voltmeter complete"
+306
"Reading Available"
+305
"High limit 2 event"
+304
"Low limit 2 event"
+303
"High limit 1 event"
+302
"Low limit 1 event"
+301
"Reading overflow"
+174
"Re-entering the idle layer"
+173
"Waiting in arm layer 2"
+172
"Waiting in arm layer 1"
+171
"Waiting in trigger layer"
+161
"Program running"
+126
"Device calculating"
+125
"Device measuring"
+124
"Device sweeping"
+123
"Device ranging"
+122
"Device settling"
+121
"Device calibrating"
+101
"Operation complete"
+000
"No error"
-100
"Command error"
-101
"Invalid character"
-102
"Syntax error"
-103
"Invalid separator"
-104
"Data type error"
-105
"GET not allowed"
-108
"Parameter not allowed"
-109
"Missing parameter"
-110
"Command header error"
-111
"Header separator error"
-112
"Program mnemonic too long"
2-8
Table 2-4
Status and error messages (cont.)
Event
Number
EE
-113
-114
SE
SE
-120
-121
EE
-123
EE
-124
EE
-128
EE
EE
-140
EE
-141
EE
-144
EE
-148
EE
-150
EE
-151
EE
-154
-158
SE
-160
SE
-161
SE
-168
SE
-170
SE
-171
SE
-178
SE
-200
SE
-201
SE
-202
SE
SE
-210
SE
-211
SE
-212
SE
-213
SE
-214
SE
-215
SE
-220
SE
-221
SE
-222
SE
-223
SE
-224
SE
-230
SE
-241
SE
-260
SE
-281
-282
EE
EE
-314
EE
-315
EE
-330
EE
-350
EE
-410
EE
-420
EE
-430
EE
-440
EE
EE
SE = Status event
EE = Error event
Description
"Undefined header"
"Header suffix out of range"
"Numeric data error"
"Invalid character in number"
"Exponent too large"
"Too many digits"
"Numeric data not allowed"
"Character data error"
"Invalid character data"
"Character data too long"
"Character data not allowed"
"String data error"
"Invalid string data"
"String too long"
"String data not allowed"
"Block data error"
"Invalid block data"
"Block data not allowed"
"Expression error"
"Invalid expression"
"Expression data not allowed"
"Execution error"
"Invalid while in local"
"Settings lost due to rtl"
(return to local)
"Trigger error"
"Trigger ignored"
"Arm ignored"
"Init ignored"
"Trigger deadlock"
"Arm deadlock"
"Parameter Error"
"Settings conflict"
"Parameter data out of range"
"Too much data"
"Illegal parameter value"
"Data corrupt or stale"
"Hardware missing"
"Expression Error"
"Cannot create program"
"Illegal program name"
"Save/recall memory lost"
"Configuration memory lost"
"Self Test failed"
"Queue overflow"
"Query interrupted"
"Query unterminated"
"Query deadlocked"
"Query unterminated after indefi-
nite response"
Event
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE

Advertisement

Table of Contents
loading

Table of Contents