IEEE-488 Reference
Parameters
Query
Description
Program fragment
3.18.11
Parameters
Query
Description
3-102
:AUTO <b>|ONCE
[:SENSe[1]]:CURRent:AC:DIGits:AUTO <b>|ONCE
[:SENSe[1]]:CURRent:DC:DIGits:AUTO <b>|ONCE
[:SENSe[1]]:VOLTage:AC:DIGits:AUTO <b>|ONCE
[:SENSe[1]]:VOLTage:DC:DIGits:AUTO <b>|ONCE
[:SENSe[1]]:RESistance:DIGits:AUTO <b>|ONCE
[:SENSe[1]]:FRESistance:DIGits:AUTO <b>|ONCE
[:SENSe[1]]:TEMPerature:DIGits:AUTO <b>|ONCE
<b> =
1 or ON
Enable auto resolution
0 or OFF
Disable auto resolution
ONCE
Enable and then disable auto resolution
:AUTO? Query state of auto resolution
These commands are used to enable or disable auto resolution for the specified function. With
auto resolution selected, the instrument automatically selects the optimum resolution for the
present integration time setting (see Tables 2-10, 2-15, 2-20 and 2-25).
The ONCE parameter is analogous to a momentary toggle switch. When :AUTO ONCE is sent,
auto resolution turns on momentarily and then disables. While enabled, resolution is selected
automatically. Auto resolution then disables but the selected value is retained.
The auto resolution command (:DIGits:AUTO) is coupled to the command that manually selects
resolution (:DIGits <n>). When auto resolution is enabled, the parameter value for :DIGits
<n> changes to the automatically selected resolution value. Thus, when auto resolution is dis-
abled, the instrument remains at the automatically selected resolution.
PRINT #1, "output 16; :volt:dc:dig:auto on; auto?"
PRINT #1, "enter 16"

:AVERage commands

The :AVERage commands are used to configure and control the filter. See paragraph 2.9 for
details.
:TCONtrol <name>
[:SENSe[1]]:CURRent:AC:AVERage:TCONtrol <name> Select filter type for ACI
[:SENSe[1]]:CURRent:DC:AVERage:TCONtrol <name> Select filter type for DCI
[:SENSe[1]]:VOLTage:AC:AVERage:TCONtrol <name>
[:SENSe[1]]:VOLTage:DC:AVERage:TCONtrol <name>
[:SENSe[1]]:RESistance:AVERage:TCONtrol <name>
[:SENSe[1]]:FRESistance:AVERage:TCONtrol <name>
[:SENSe[1]]:TEMPerature:AVERage:TCONtrol <name>
<name> = REPeat
Select repeating filter
MOVing
Select moving filter
:TCONtrol? Query filter type
These commands are used to select the type of averaging filter (REPeat or MOVing) for the
specified function.
Control auto resolution for ACI
Control auto resolution for DCI
Control auto resolution for ACV
Control auto resolution for DCV
Control auto resolution for
2
Control auto resolution for
4
Control auto resolution for TEMP
' Enable auto resolution
' Get response from 2002
Select filter type for ACV
Select filter type for DCV
Select filter type for
2
Select filter type for
4
Select filter type for TEMP