Adjusting the Magnetic TOF

Use this setting to position the magnetic data at the correct distance from the leading edge of
the card.
The Magnetic TOF is the distance from the edge of the card to the Start Sentinel (SS).
The Start Sentinel marks the beginning of the encoded data. (Note: According to the
magnetic recording standard (ISO 7811), the correct Start Sentinel distance is 0.293
inches ± 0.020 inches (7.44 mm ± 0.51 mm) from the leading edge of the card.)
Step
Procedure
1
From the application program, print and encode a test card.
Measure this distance by making the data visible using a magnetic
viewer or developer solution.
Alternatively, use a Magnetic Card Analyzer to measure the Start
Sentinel distance.
2
If the Start Sentinel is too far from the leading edge of the card,
reduce (or make negative) the Magnetic TOF.
OR
If the Start Sentinel is too close to the leading edge of the card,
increase (or make positive) the Magnetic TOF.
3
Select MENU, Setup Printer, Encoder Settings and Magnetic TOF.
4
Record the Magnetic TOF value on the test card last printed.
DTC550 Direct to Card Printer/Encoder User Guide (Rev. 2.8)