Operation Modes; Operation Mode; Delegate Interrupt Mode; User Manual Cu 6105.Docx - Danish Interpretation Systems DCS 6000 User Manual

Digital conference system central unit
Hide thumbs Also See for DCS 6000:
Table of Contents

Advertisement

DIS
6.6

Operation Modes

The "Operation Mode" determines the behavior of the
6.6.1

Operation Mode

microphone system.
Auto (or Automatic) mode allows for the
Conference units to be switched on immediately
upon activating the 'Speak' button.
This is indicated by a red light in the 'Speak' lamp
and in the light ring in the gooseneck
microphone. Activating the 'Speak' button again
will turn the microphone off
A Chairman Unit can be considered as is always
being in Auto or VOX mode.
Manual mode features a request list, where
'Delegates' are inserted in a queue upon
activating the 'Speak' button. This is confirmed by
a steady green light in the 'Request' indication in
the delegate unit. It is possible to cancel the
request by activating the button again.
The delegate unit can only be switched 'On' using
the CU 6105 browser interface on a PC/iPad or
from SW 6000 or from a control system like AMX
® or Crestron ®. This will be indicated by red
light in the 'Speak' lamp in the Conference unit. At
this point the delegate can switch off the
microphone by activating the 'Speak' button.
Note: Manual mode is normally never selected/used
on CU 6105 if a Browser, AMX ®, Crestron ® or other
"Control Facility" is not connected.
FIFO is an automated mode. The Conference unit
functions in the same way as in 'automatic' mode
as long as the number of turned on delegate units
is less or equal to the selected maximum
speakers.
When the max. number is reached, the next
delegates activating their 'Speak' button will be
placed in the request queue until the maximum
requests is reached. The green 'Request' lamp in
the delegate unit in top of the queue will flash
slowly indicating that this unit is the next to be
switched 'On'
6.6.2
The "Delegate Interrupt" setting determines the
behavior of the delegate Conference units.

User Manual CU 6105.docx

The green 'Request' lamp in the other delegate
unit in the queue will light up steadily.
When one of the units speaking is switched 'Off',
the first delegate unit in the queue is automati-
cally switched 'On'.
This mode will normally be used with only 1 as
'Max delegate speakers'. Chairman units will
always be turned on directly if the value set for
'Max Total Speakers' is not reached.
VOX, voice activation mode allows for the
Conference units to be switched on automatically
when a delegate is speaking in the microphone or
by activating the 'Speak' button.
This is indicated by a red light in the 'Speak' lamp
in the Conference unit. Activating the microphone
'Speak' button again will turn the microphone off.
When a delegate stops speaking the microphone
turns off automatically after a short period. This
period is controlled by the 'Release Time' setting
(see section '6.5 Web Browser Setup and Control'),
where default is 4 seconds.
The microphone can also be turned off by
activating the 'Speak' button.
A Chairman Unit can be considered as always
being in Auto or VOX mode

Delegate Interrupt Mode

None When "None" is selected and the number of
open Delegate units has reached the number
specified in the setting "Max. Delegate Speakers"
no more delegate microphone can be opened.
Pressing the microphone buttons will not turn on
the microphone but 3 flashes in the green LED
will indicate, that the maximum number has been
reached.
It is similar for Chairman units if the number of
open units (Chairman and Delegate) has reached
the number specified in the setting "Max. Total
Speakers".
User Manual