Danish Interpretation Systems User Manual List of Contents Operating instructions.......... 7 List of Contents ............. 3 JB 6002/04 Junction Box ........7 Document version ..........3 General description.......... 7 Important............... 4 Features ............7 Compliancy ............4 Connectors JB 6002/04 ........7 Installation precautions........
Danish Interpretation Systems User Manual Important exposed to direct sunlight, excessive dust or Compliancy humidity, mechanical vibration or shock. To avoid moisture condensations do not install the The equipment has been tested and found to comply unit where the temperature may rise rapidly. with the limits of the following standards for digital devices: Cleaning...
Danish Interpretation Systems User Manual Description of the DCS 6000 system RS232/RS422 connection on CU 6010 for external Features operation of the system of a PC or control system such as AMX or Crestron The DCS 6000 system has the following main The SW 6000 is an optional software package, features: which expands the functionality of the DCS 6000...
Danish Interpretation Systems User Manual Conference equipment and channel System components selectors The CU 6010 Central Unit supports all available CS 6032FV/H Channel Selector (flush mounted) units in the DCS 6000 series: CM/DM 6010P Conference Unit (portable) CM/DM 6020P Conference Unit (portable) with Central equipment etc.
Danish Interpretation Systems User Manual Operating instructions Each connector is for connection to one Delegate JB 6002/04 Junction Box Unit or one Interpreter Unit or up to four Channel Selectors. This limitation is because the ‘Unit’ General description connectors have current limiting devises for the power line.
Danish Interpretation Systems User Manual Standard use of JB 6002/04 The following typical schematic shows the normal use of JB 6002/04 with delegate and interpreter units: Manual 01 18 04453...
Danish Interpretation Systems User Manual Enhanced use of JB 6002/04 The following schematic shows how to use two there will always be units (in the same row or parallel feeding cables to both the delegate units booth), which will work. This considerably and the interpreter units.
Danish Interpretation Systems User Manual Appendix Technical appendix Pair 1: Pin 1 & 2 Cabling Pair 2: Pin 3 & 6 Pair 3: Pin 4 & 5 CAT5 Pair 4: Pin 7 & 8 The DCS 6000 system uses CAT5, CAT5e or The phase of the pairs must be correct and CAT6 FTP or STP cables with screened RJ45 the wiring spec.