General Guidelines; Installation; Cabling Guidelines - Danish Interpretation Systems DCS 6000 User Manual

Digital conference system central unit
Hide thumbs Also See for DCS 6000:
Table of Contents

Advertisement

DIS
7.
Type in the internet browser: 'http://IP-
address', where 'IP address' is the address
noted from the CU 6105
8.
The CU 6105 browser interface will open.
5

General Guidelines

5.1

Installation

The CU 6105 is suitable for either table-top or 19-
inch rack-mounted use. Four feet (for table top use)
and two mounting brackets (for rack mounting) are
supplied.
When installing in a 19" rack the supplied 19"
brackets shall be fixed to the front side of the CU 6105
Central Unit by unscrewing the crews holding the top
and button cover and then fix the brackets using the
same screws.
The unit has a low noise built-in fan taking air in at
the left side of the unit and blowing the hot air out at
the right side. That allows units in 19" racks to be
5.2

Cabling guidelines

The Conference Units are connected to the CU 6105
Central Unit using Cat5e F/UTP or U/FTP screened
cables and the following guidelines have to be
observed:
The Conference units are daisy chain connected
to the central unit
The number of units, which can be connected to
CU 6105, depends on length of the feeding cable
and the length of the cable between each unit.
If the feeding cables are short and the cables
between the units are short, more units can be
connected than if the feeding cable is long and/or
the cables are long between the units.
Maximum cable length in one chain is 200 m
(before inserting RP 6004 Repeater in a chain).
This includes interconnection cables between the
units.
Maximum cable length in one chain when using
RP 6004 Repeaters and Cat5e cables is 680 m.
12
Please refer to section '6.5 Web Browser Setup and
Control' for details about using the CU 6105 web
browser.
stacked close with other units without extra room for
cooling air between them.
Please check that other units in the rack will allow
this.
Connect the CU 6105 to the various DCS 6000 units
using CAT5e cabling (F/UTP or U/FTP) screened
cables following the guidelines in the next chapter.
The operation and installation of the various DCS
6000 units is found in the User Manuals for the
specific units.
Although the DCS-LAN chain output connectors have
a 125 W supply, this 125 W power is not all available
with long cables, as there will be a power drop in the
User Manual CU 6105.docx
Cables must be AWG24 if the number of units in
the tables in section '5.3 Max. number of units to
be connected' is to be used. AWG26 cables will not
allow as many units. DIS cables series EC 6001-xx
are all AWG 24.
It is desirable that the square of the feeding
cables are as big as possible to minimize the
voltage drop in the cables. Cat5e cables are
delivered in various gauges:
The following table shows the Diameter/square
for various AWG types:
AWG22
0.64 mm
Type
Diameter
AWG23/1
0.57 mm
AWG24
0.53 mm
AWG26
0.42 mm
User Manual CU 6105
0.32 mm2
Square
0.25 mm2
0.22 mm2
0.14 mm2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu 6105