Danish Interpretation Systems DCS 6000 User Manual

Danish Interpretation Systems DCS 6000 User Manual

Digital conference system central unit
Hide thumbs Also See for DCS 6000:
Table of Contents

Advertisement

DCS 6000

User Manual

CU 6005/6010/6011 Central Unit
Central Unit for series DCS 6000 Voting Units, Conference
Units, Interpreter Units, Ambient Noise Microphone, Channels
Selectors and Audio Output Units
Danish Interpretation Systems
Digital Conference System
DIS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DCS 6000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danish Interpretation Systems DCS 6000

  • Page 1: User Manual

    DCS 6000 User Manual Digital Conference System CU 6005/6010/6011 Central Unit Central Unit for series DCS 6000 Voting Units, Conference Units, Interpreter Units, Ambient Noise Microphone, Channels Selectors and Audio Output Units Danish Interpretation Systems...
  • Page 2 Danish Interpretation Systems User Manual Copyright © 2008 DIS CU6005 6010 6011 REV Z 26-09-2008 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.
  • Page 3: Table Of Contents

    CM/DM 60x0P Chairman/Delegate Units – CU Repacking ............8 6010/6011 ............27 Warranty ............8 CM/DM 60x0P Chairman/Delegate Units – CU Description of the DCS 6000 system ....9 6005 ...............27 Features.............. 9 CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box – CU 6010/6011....27 System components.........
  • Page 4 Technical specifications.........41 Various configurations with RP 6004 Repeater and PS 6000 Power Supply ......36 Copyright © 2008 DIS CU6005 6010 6011 REV Z 26-09-2008 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the...
  • Page 5: Important

    Danish Interpretation Systems User Manual Important 9 Do not install near any heat sources such as Important Safety Instructions radiators, heat registers, stoves, air ducts, or other apparatus (including amplifiers) that 1 Read these instructions - All the safety and produce heat.
  • Page 6: Labels

    For apparatuses intended to operate within the operating voltage of the unit. If a voltage from battery power, or other sources, refer to the conversion is required, consult your DIS dealer or operating instructions. qualified personnel. 22 Power Lines - An outdoor system should not be...
  • Page 7: Power Disconnect

    Danish Interpretation Systems User Manual The device complies with part 15 of the FCC rules. The equipment must be connected to earth Operation is subject to the following conditions: (1) (ground). The device may not cause harmful interference, and The wires in the main lead supplied with the (2) the device must accept any interference equipment are coloured in accordance with the received, including interference that may cause...
  • Page 8: Repacking

    Danish Interpretation Systems User Manual Repacking Save the original shipping cardboard box and packing material; they will become handy if you ever have to ship the unit. For maximum protection, re-pack the unit as originally packed from the factory. Warranty The unit is minimum covered by 12 months warranty against defects in materials or work- manship.
  • Page 9: Description Of The Dcs 6000 System

    Added functionality comprehensive Features features provided by SW 6000 software package running on PC The DCS 6000 system has the following main features: RS232/RS422 connection 6005/6010/6011 for external operation of the Fully digital system of a PC or control system such as AMX...
  • Page 10: System Components

    Conference equipment and channel System components selectors The CU 6005/6010/6011 Central Unit supports all CS 6032F V/H Channel Selector (flush mounted) available units in the DCS 6000 series: DC 6990P Conference Unit (portable) with touch screen Central equipment etc. DM 6010P...
  • Page 11: Operating Instructions

    Mains supply. General description Designed in a standard 2HE 19” cabinet. The CU 6011 Central Unit for the DCS 6000 is the Functionality on the CU 6011 depends on the heart of the system. One CU 6011 is needed in each Feature License uploaded into the unit.
  • Page 12: User Controls, Indications & Connectors

    Danish Interpretation Systems User Manual User Controls, indications & connectors Front plate layout The front plate layout of the CU 6011 Central Unit consists of a large illuminated LCD display and 8 buttons for setting up/controlling the system: Details of display -Audio Control -Delegate setup -Interpreter setup...
  • Page 13 Danish Interpretation Systems User Manual Buttons ‘-‘ The buttons below and to the left of the display are The dash symbol (‘-‘) preceding a line of text used when stepping through the different menus identifies a submenu or a changeable parameter. and for setting up the system: The submenu or parameter can be selected by pressing the corresponding select button.
  • Page 14: System Settings

    Danish Interpretation Systems User Manual Back Panel Layout Back Panel Connectors Interpreter sets for those languages have to be connected to Chain B1 or B2. Mains Power connector Chain B1 & B2 Connection for mains power. See specs. RJ45 connector, 2 pieces Analog Audio Line input DCS-LAN connectors for connection to DM/CM XLR Input connector.
  • Page 15 Danish Interpretation Systems User Manual A selection is made in the Main menu by scrolling The Audio Control menu comprises the following through the menu items with the Up/Down buttons, complete list of adjustment items: and pressing the Select button associated with the Loudspk volume desired menu item.
  • Page 16 Danish Interpretation Systems User Manual Delegate setup Values: {Auto, Manual, FIFO, VOX}: “Delegate setup” menu comprises Auto (or Automatic) mode allows for the following entries: microphone units to be switched on immediately upon pressing the microphone Max Speakers ON/OFF button. Max.
  • Page 17 Danish Interpretation Systems User Manual More delegates will be put in the request but 3 flashes in the green LED will indicate, that the queue when they press their ON/OFF maximum number has been reached. buttons, until the maximum of requests is It is similar for Chairman units if the number of reached.
  • Page 18 Danish Interpretation Systems User Manual This setting is used to set the time from the delegate When set to 0 value no interpretation channels are stops talking until the microphone turns off. The present in the system. Only ‘Floor’ sound will be default value is 4 sec.
  • Page 19 Danish Interpretation Systems User Manual Complete Lock Transmission ambient noise rather than transmitting no sound at all is a desirable feature With this setting an interpreter cannot switch on his from listeners attending meeting microphone to any occupied interpreter channel. headphones.
  • Page 20 Danish Interpretation Systems User Manual The Chain info menu displays information to the The “Input mode” defines whether the ASCII user about units connected to the CU. The communication via RS232/RS422 is protected by information is divided into Chain A, Chain B and CRC check or not.
  • Page 21 Danish Interpretation Systems User Manual The load is aborted with the Menu button and When switching the power to the CU 6011 OFF and accepted with the Enter button. In both cases, the then ON, the last saved setting will also be loaded. menu system returns to the Main menu.
  • Page 22: Normal Operation

    Danish Interpretation Systems User Manual The user returns to the main menu by pressing This screen is the standard screen showed at normal either the Menu button or the Enter button. use. This screen is automatically shown if no buttons is pressed in 2 minutes. The function of this screen is explained in the section Audio Control Normal Operation menu.
  • Page 23: Cu 6010 Central Unit

    Danish Interpretation Systems User Manual The LinelnLevel Adj has to be set as high as >LoudSpk is used for setting the audio level needed possible for maintaining the best S/N ration, but not in the loudspeakers. too high to avoid clipping, whereas the LineIn- CU 6010 Orignal Audio Volume Control Units CU 60XX...
  • Page 24: Cu 6005 Central Unit

    Danish Interpretation Systems User Manual Controls up to max. 500 Conference/Voting CU 6005 Central Unit units. Controls of Interpreter Sets or other controllable units are as for CU 6011. General description Designed for up to 16 interpreted channels (instead of 31) and 8 open microphones The functionality of CU 6005 is basically identical Built in Power Supply for app 50 Conference to the CU 6011 Central Unit;...
  • Page 25: User Controls, Indications & Connectors

    Danish Interpretation Systems User Manual User Controls, indications & connectors Front plate layout Identical to the CU 6011 Central Unit. Front plate controls Identical to the CU 6011 Central Unit. Back Panel Layout Back Panel Connectors System settings As the CU 6011 Central Unit with the following differences: The same as for the CU 6011 Central Unit.
  • Page 26: System Setup

    DCS 6000 units using Cat5 or Cat5e FTP or STP section ‘Maximum number of units to be screened cables. connected’. The operation of the DCS 6000 units is found in the The maximum number of languages User Manual for the specific units.
  • Page 27: Maximum Number Of Units To Be Connected

    Danish Interpretation Systems User Manual Maximum number of units to be connected The following table shows the maximum number of Central Unit or on each output on an EX 6010 units, which can be connected to each of the four Extension Unit or on the output of a PS 6000.
  • Page 28: Cm/Dm 60X0P Chairman/Delegate Units & Jb 6004 Junction Box - Cu 6010/6011

    Danish Interpretation Systems User Manual Length of Feeding Cable, Length of Cable between each Total cable Number of Max. number of Type CAT5 AWG24 JB 6002, Type CAT5 AWG24 length JB 6002 DM 60x0 10 m 61 m 30 m 75 m 50 m 89 m...
  • Page 29: Cm/Dm 6560F Chairman/Delegate Units - Cu 6010/6011

    Danish Interpretation Systems User Manual CM/DM 6560F Chairman/Delegate Units – CU 6010/6011 The following table shows the maximum number of Central Unit or on each output on an EX 6010 units, which can be connected to each of the four Extension Unit or on the output of a PS 6000.
  • Page 30: Dc 6990P Conference Units - Cu 6010/6011

    Danish Interpretation Systems User Manual DC 6990P Conference Units – CU 6010/6011 The following table shows the maximum number of Central Unit or on each output on an EX 6010 units, which can be connected to each of the four Extension Unit or on the output of a PS 6000.
  • Page 31: Mu 6040C/D And Mu 6042D Without Connected Loudspeaker - Cu 6010/6011

    Danish Interpretation Systems User Manual MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011 This table shows the maximum number of MU The numbers are valid with no audio in loudspeaker 6040 Microphone Units, which can be connected to (no loudspeaker connected to each unit).
  • Page 32: Is 6132P W/Jb 6004 And Ls 6032 - Cu 6010/6011

    Danish Interpretation Systems User Manual IS 6132P w/JB 6004 and LS 6032 – CU 6010/6011 Length of Feeding Cable, Length of cable Number of Number of Number of Type CAT5 AWG24 between booths booths IS 6132/ booths LS 6032/ booths 10 m 10 m 30 m...
  • Page 33: Typical Schematics

    Danish Interpretation Systems User Manual Typical schematics The following schematics are showing various configurations: Small conference microphone system with CU 6005 Small conference microphone system with CU 6011 Manual 01 18 04438...
  • Page 34: Large Size Conference Microphone System

    Danish Interpretation Systems User Manual Large size conference microphone system Microphone conference system with interpretation CU 6011 Manual 01 18 04438...
  • Page 35: Microphone Conference System With 3+1 Ch. Interpretation & Ir, Cu 6005

    Danish Interpretation Systems User Manual Microphone conference system with 3+1 ch. interpretation & IR, CU 6005 Microphone conference system with 15+1 ch. interpretation & IR, CU 6011 Manual 01 18 04438...
  • Page 36: Various Configurations With Rp 6004 Repeater And Ps 6000 Power Supply

    Danish Interpretation Systems User Manual Various configurations with RP 6004 Repeater and PS 6000 Power Supply Manual 01 18 04438...
  • Page 37: Small System With Sw 6000 Conference Management Software

    Danish Interpretation Systems User Manual Small system with SW 6000 Conference Management Software Manual 01 18 04438...
  • Page 38: Large System With Sw 6000 Conference Management Software

    Danish Interpretation Systems User Manual Large system with SW 6000 Conference Management Software Manual 01 18 04438...
  • Page 39: Appendix

    CAT6 can thus only be used for longer cable draws Cabling terminating in wall outlets or patch panels. CAT5 RS 232 Serial connection The DCS 6000 system uses CAT5, CAT5e or RS232 on CU RS232 on PC CAT6 FTP or STP cables with screened RJ45 6005/6010/6011 connectors.
  • Page 40: Accessories (Not Supplied)

    EC 6000-02 Connection Cable 2 m......10 03 13201 Signal Cable type EC 6000-05 Connection Cable 5 m......10 03 13501 Ground DIS type #2914 EC 6000-10 Connection Cable 10 m.......10 03 14102 In phase signal or 2 x 0.25 mm EC 6000-20 Connection Cable 20 m.......10 03 14202 shielded.
  • Page 41: Technical Specifications

    Dimensions in bracket are including 19” brackets Slot dimensions (W x H x D) ..180 x 38 x 120 mm (CU 6005) The DCS 6000 system conforms to all relevant standards - Accessories supplied ..........User manual e.g. IEC 914, ISO 4043, and ISO 2603 .................Mains cable...
  • Page 42 Danish Interpretation Systems User Manual Manual 01 18 04438...