Danish Interpretation Systems
carrying floor audio (because there is no
interpretation taking place on the channel). The
attenuation level can be adjusted between -20 and 0
dB. The 0 dB setting is used when no attenuation is
desired. When selecting Off the output is muted.
Lock feature
A feature is included to hide part of the set-up menu
from the user. The lock can be enabled/disabled
locally from the unit by pressing a predefined key
combination.
When in locked mode the user only has access to
the "Headphone", "Ver. and serial no." and
"Communication" menus and is thereby unable to
make any changes to the unit configuration. The
unavailable menu entries will not have a "-" sign to
the left of the entry:
Channel setup
Volume setup
-Headphone setup
-Communication status
If the user presses one of the disabled menu entries
the "Unit locked!" message is shown for three
seconds.
The lock is activated from the unit by holding the
ENTER button depressed for five seconds in the
set-up menu display. This brings up a confirmation
display for three seconds:
Unit locked!
The unit is unlocked in the same way by holding the
ENTER key depressed and a confirmation display
is shown:
Unit unlocked!
12
The lock status is being saved in the CU 6010 and
retransmitted to the unit after power up.

Normal operation

Normal Operation Display
In normal operation the user must be able to check
the language setting of all the output channels from
a single display without pressing any buttons. This
is the Normal Operation Display:
This display indicates which language-channel has
been assigned for each of the 8 outputs. And the
filled square indicates the channel, where the
headphone is monitoring. Use the up (▲) and down
(▼) buttons to select the headphone monitoring
channel.
If an output is set to a language that no longer exists
the language indication will be "---". The user can
then choose a new language for the channel. If no
buttons have been pressed for 2 minutes the display
will change to shown the Normal Operation display.
The user has access to the following functions, by
pressing the Menu button:
Refer to Setup section for information in how to
setup the system using the above menus.
Manual 01 18 04440
A: 12ALB
E: 13DAN
B: 14ENG
F:
■ C: 15NOR■
G:
D:
0FLO
H:
Menu
Language for each output channel.
Volume setting for each channel.
Monitoring output and volume for headphone.
Communication status.
Unit info.
Load/save of configuration.
Original Attenuation.