Chain Max. Number Of Units To Be Connected - Danish Interpretation Systems DCS 6000 User Manual

Digital conference system central unit
Hide thumbs Also See for DCS 6000:
Table of Contents

Advertisement

DIS
feeding cable from the CU 6105 Central Unit to the
units connected.
5.3
Max. number of units to be connected
The following tables shows the maximum number of
units, which can be connected to a CU 6105 Central
Unit.
In the tables the 'Feeding Cable' is defined as the
cable between the CU 6105 and the first Conference
Unit and the 'Interconnecting Cable is defined as the
cable connecting two conference units.
5.3.1
Connection using only one
The following tables show the maximum number of
DCS-LAN chain
units, which can be connected to one DCS-LAN chain
output when only one DCS-LAN chain is in use.
5.3.1.1
DC 6120 P, DC 6190 P, DM 6680 P
Conference Units
Length of
Length of inter
Feeding Cable
connecting
Type CAT5e
Cable, Type
AWG24
CAT5e AWG24
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 5.3-A
DC 6120 P, DC 6190 P or DM 6680 P
Conference Units connected
Total cable
Max. number
length
of units pr
output
51 m
42
67 m
38
83 m
34
122 m
23
165 m
16
88 m
40
98 m
35
108 m
30
140 m
21
178 m
15
User Manual CU 6105.docx
Please consult the next sections for details about the
number of units, which can be connected depending
on the cable length.
5.3.1.2
DC 6990 P Conference Unit
Length of
Length of inter
Feeding Cable
connecting
Type CAT5e
Cable, Type
AWG24
CAT5e AWG24
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 5.3-B
DC 6990 P Conference Units connected
5.3.1.3
CM/DM 6080 F / DM 6620 F
Chairman/Delegate
Length of
Length of inter
Feeding Cable
connecting
Type CAT5e
Cable, Type
AWG24
CAT5e AWG24
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
150 m
1 m
10 m
2 m
30 m
2 m
50 m
2 m
100 m
2 m
150 m
2 m
Figure 5.3-C
CM/DM 6080 F or DM 6620 F
Chairman/Delegate Units connected
User Manual CU 6105
Total cable
Max. number
length
of DC 6990 P
per output
35 m
22
53 m
22
70 m
21
112 m
13
158 m
9
56 m
25
72 m
22
90 m
19
124 m
13
166 m
9
Total cable
Max. number
length
of DC 61xxP
per output
39 m
30
56 m
27
73 m
24
115 m
16
160 m
11
64 m
28
78 m
25
94 m
23
130 m
16
170 m
11
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu 6105