DCS 6000 User Manual Digital Conference System EX 6010 Extension Unit Extension power supply with repeater for increasing the system capacity in DDS 5900 and DCS 6000 Systems...
Max. number of units to be connected ....15 DCS 6000 Conference System ........8 Typical schematics ........... 17 Description of the DCS 6000 system...... 8 Central equipment etc............ 9 EX 6010 versus RP 6004 Repeater and PS 6000 System components ............
User Manual Important Important Safeguards Read these instructions - All the safety and operating instructions should be read before or other apparatus (including amplifiers) the apparatus or system is operated. that produce heat. Keep these instructions - The important Do not install the unit in a place exposed to safety instructions and operating instructions direct sunlight, excessive dust or humidity, should be retained for future reference.
User Manual CU 6105 Object and Liquid Entry - Never push objects of any kind into this apparatus through Unplug this apparatus during lighting time. – Not applicable when special functions openings as they may touch dangerous voltage storms or when unused for long periods of are to be maintained, such as evacuation points or short-out parts that could result in a systems.
User Manual CU 6105 Blue Neutral For pluggable equipment, the socket-outlet shall be Brown Live installed near the equipment and shall be easily accessible. The green-and-yellow wire must be connected to the terminal in the plug marked with the letter E or with the safety earth symbol or marked with green-and- yellow color.
User Manual CU 6105 Warranty The units are minimum covered by 24 months warranty against defects in materials or work- manship. User Manual EX 6010 rev F.doc...
User Manual CU 6105 DCS 6000 Conference System Description of the DCS 6000 system DCS 6000 Digital Conference System is a system to be Delegate and Interpreter units are powered and used at meetings, where a number of people are controlled by the CU 6105 or CU 6110 Central •...
FD/FC front plate with System components The CU 6105 Central Unit supports all available units Loudspeaker, Microphone and in the DCS 6000 series: Buttons. Available in Delegate (D) and Chairman (C) version MU 6042 D Dual Microphone Unit for use with FD/FC front plate with Central equipment etc.
The main features of the EX 6010 Extension Unit are: Power Supplies, Repeater and Splitter functionality for the DCS 6000 system. One CU 6105 or CU 6110 Built in Power Supplies for app 200 units Central Unit is needed in each DCS 6000 system, (Delegate) or app.
User Manual CU 6105 Back panel layout Those LED’s light up when Power is available on the Connectors Power LED’s connector next to the LED and only if the voltage is Connection for mains power. See specs. over 24V (not overloaded). ...
Danish Interpretation Systems User Manual System design There are no settings to be done on the EX 6010 6110, the max. number of languages configured on Extension Unit. the four outputs (1, 2, 3 and 4) is totally max. 16. However it is important to observe, that the unit is If more languages are required, Interpreter sets for only repeating one of the chains on the CU 6105 or CU...
Danish Interpretation Systems User Manual When connecting a number of EX 6010 Extension ‘Loop through’ connection Units to the CU 6105 or CU 6110 an almost unlimited number of EX 6010 can be connected by using the ‘Loop through’ connector. However the practical limitation is the maximum cable length in one chain, which is 200 m and the supply of power to the ‘Loop Through’...
When installing in a 19” rack the supplied 19” this. brackets shall be fixed to the front side of the CU 6105 Connect the EX 6010 to the various DCS 6000 units Central Unit by unscrewing the crews holding the top using CAT5e cabling (F/UTP or U/FTP) screened and button cover and then fix the brackets using the cables following the guidelines in the next chapter.
User Manual Max. number of units to be connected The following tables shows the maximum number of units, which can be connected to a CU 6105 Central 30 m 72 m Unit. 50 m 90 m In the tables the ‘Feeding Cable’ is defined as the 100 m 124 m cable between the EX 6010 and the first Conference...
Page 16
User Manual MU 6040 C/D and MU 6042 D IS 6132 P Units and JB 6104 Length of Cable length Total cable Max. number Length of Length of Number Number Number of Feeding Cable, between each length of MU 6040 Feeding Cable, cable of IS...
User Manual Typical schematics The following schematics are showing a typical configuration with use of EX 6010. Figure 0-A System with EX 6010 EX 6010 versus RP 6004 Repeater and PS 6000 Power Supply The next schematic shows, that the functionality of the EX 6010 equals one RP 6006 Repeater and four PS 6000 Power Supplies.
User Manual Technical Specifications Unit Specification Power consumption ............max. 600W To guarantee specified performance ..5 Deg C. to 40 Deg C. General Temperature range In-rush current ....max. 30A @115V or max. 60A@230V Storage temperature ........-20 Deg C. to 60 Deg C Mains voltage: ..........
GRN/WHT Brown Live Green/Yellow Earth (Ground) BLU/WHT BLU/WHT +48V The DCS 6000 system uses Cat5e, Cat6 or Cat7 F/UTP DCS-LAN Chain Outgoing - BRN/WHT BRN/WHT or U/FTP cables with screened RJ45 connectors. Outgoing + EIA 568-B wiring shall be used.