2-16 General Description
Others
Memory capacity displayed on the OS = total capacity of physically installed memory –
capacity for standby memory
Memory mirroring feature: 1/2 of actually installed memory capacity
Memory RAID feature: 3/4 of actually installed memory capacity
Enabling the memory mirroring or memory RAID feature does not influence the
operations of applications.
The each feature is automatically disabled when an error message is displayed:
The following indicates that the memory mirroring /memory RAID feature has worked:
a) The Redundancy lamp on the front panel of the server lights green.
b) The failing DIMM group is degraded when the server restarts.
c) If NEC ESMPRO Agent has been installed, the following log is registered as a system
log of Event Viewer:
Source name:
Event ID:
Explanation:
Memory number: XX
Date/time:
d) If report setting is made through NEC ESMPRO Agent, Manager reporting and
ALIVE reporting is performed. The report contents are as follows:
Explanation:
Memory number: XX
Date/time:
ESMCommonService
2313
Part of the DIMM was isolated due to a memory error.
XX
Part of the DIMM was isolated due to a memory error.
XX