NEC N8100-1223F User Manual page 114

Express5800/140hf
Table of Contents

Advertisement

4-26 Configuring Your Server
Option
Parameter
Boot
[Disabled]
Monitoring
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Boot
[Retry 3 Times]
Monitoring
Retry Service Boot
Policy
Always Retest
Thermal
Disabled
Sensor
[Enabled]
BMC IRQ
Disabled
[IRQ 11]
Post Error
Disabled
Pause
[Enabled]
AC-LINK
Stay Off
[Last State]
Power On
Power ON
[0] - 255
Delay Time
FRU LED
Disabled
Feature
[Enabled]
Clear FRU
[No]
LED
Yes
Platform
Disabled
Event
[Enabled]
Filtering
Description
Indicates whether the boot monitoring
function is enabled or disabled on booting.
To use this function, install NEC ESMPRO
Agent. Do not use this function if the system
is booted from OS without installation of NEC
ESMPRO Agent or CD-ROM. Set this item to
"Disabled" if ARCServe uses the Disaster
Recovery Option.
Appears when the boot monitoring feature is
enabled. This item indicates the processing
at the occurrence of timeout during boot
monitoring.
If [Retry 3 times] is selected, the system is
reset after the occurrence of timeout and OS
boot is retried up to three times. The failure in
the third boot causes the boot to be tried from
the service partition.
If [Retry Service Boot] is selected, the system
is reset after the occurrence of timeout and
OS boot is retried up to three times. Then the
boot is tried from the service partition for
three times.
If [Always Reset] is selected, the system is
reset after the occurrence of timeout and OS
boot is retried repeatedly.
Indicates whether the temperature sensor
monitoring function is enabled or disabled.
Indicates the IRQ of the BMC interrupt.
Indicates whether POST is aborted once at
the end of POST if an error occurs during the
execution of POST.
Indicates the AC-LINK function. Shows the
state of the power of the server.
Sets the power on delay time when "Power
On" or "Last State" is specified for AC LINK.
Select "Enabled" to turn on the error lamp to
identify the location if the system detects a
failure.
Select "Yes" to turn off the FRU LED. When
the faulty component is replaced, turn off the
FRU LED.
Enables or disables the Platform Event
Filtering feature of the baseboard
management controller (BMC).