NEC N8100-1223F User Manual page 339

Express5800/140hf
Table of Contents

Advertisement

There are some cases that an event log concerning the SAS device is registered in application
log of Event Viewer during operation.
Event Source: MR_MONITOR
Event Type:
Event ID:
Description: Controller ID:a Unexpected sense PD=b:c , CDB=0xXX, ...,
a: Controller number of LSI Logic MegaRAID SAS PCI EXPRESS ROMB
Normally, the controller ID is "0". It depends on the number of disk array controller
cards N8103-90 installed in PCI-Express slot.
b: SAS port number of LSI Logic MegaRAID SAS PCI EXPRESS ROMB
(1: Port 0-3, 2: Port 4-7)
c: Slot number for the device
This message indicates that the command issued to SAS device is abnormally ended.
→ Normally the command is retried, therefore, it is not a problem in operating the
system.
This message may be logged when SAS hard disk drive that has not been configured
is removed from the slot.
→ It is not a problem in operating the system.
If the message is displayed again for the specific hard disk drive, check if the hard
disk drive is connected correctly.
→ If the same error message appears repeatedly, contact your service representative
to replace the hard disk drive.
There are some cases that an event log is registered in MegaRAID Storage Manager (MSM) log
at startup of OS after rebuilding the hard disk drives with WebBIOS.
Controller ID:x VD is now DEGRADED VD x.
→ It is not a problem in operating the system.
A popup message may appear if the notification feature for NEC ESMPRO
Manager is enabled.
Warning
113
Sense=0xXX, ...
Troubleshooting 8-45

Advertisement

Table of Contents
loading

Table of Contents