Chapter 2: Convenient Features Useful features and the detail of system BIOS settings, RAID Configuration Utility, and EXPRESSBUILDER Chapter 3: Appendix Error messages and Windows Event Logs Other documents Provides the detail of NEC ESMPRO, Universal RAID Utility, and the other features. Express5800/GT110e User’s Guide...
Contents Contents Documents Provided with This Product ......................... 2 Contents ................................3 Notations Used in This Document ......................... 7 Notations used in the text ..........................7 Optical disk drives ............................7 Hard disk drives ............................7 Removable media ............................7 Abbreviations of Operating Systems (Windows) ...................
Page 4
Contents Names and Functions of Parts ........................32 Front View ............................32 Rear View ............................33 Internal View ............................ 34 Motherboard ............................ 36 Status Indicators ..........................37 4.5.1 POWER LED ( ) ......................37 4.5.2 STATUS LED ( ) ......................37 4.5.3 Disk Access LED ( ) .....................
Page 5
Contents 1.10 PCI Card ............................61 1.10.1 Notes ..........................62 1.10.2 List of option devices and installation slots ................ 63 1.10.3 Installation.......................... 65 1.10.4 Configuration after installing ....................67 1.10.5 Removal ..........................67 1.10.6 Installing the N8117-01A additional RS-232C connector kit ..........68 1.11 3.5-inch Hard Disk Drive ........................
Page 6
Contents Chapter 3 Setup ..............................104 Turning on the Server ..........................105 POST ............................. 106 1.1.1 POST sequence ......................106 1.1.2 POST Error Messages ..................... 108 System BIOS Setup ..........................109 Overview ............................109 Starting SETUP Utility ........................109 Description on On-Screen Items and Key Usage ................110 Cases that Require Configuration ....................
Notations Used in This Document Notations Used in This Document Notations used in the text In addition to safety-related symbols urging caution, 3 other types of notations are used in this document. These notations have the following meanings. Important Indicates critical items that must be followed when handling the server or operating software. If the procedures described are not followed, server failure, data loss, and other serious malfunctions could occur.
Notations Used in This Document Abbreviations of Operating Systems (Windows) Refer to Chapter 1 (1.2 Supported Windows OS) in Installation Guide (Windows) for detailed information. Notations in this document Official names of Windows Windows Server 2008 R2 Standard Windows Server 2008 R2 Windows Server 2008 R2 Enterprise Windows Server 2008 R2 Foundation Windows Server 2008 Standard...
Trademarks Trademarks EXPRESSSCOPE is a registered trademark of NEC Corporation. Microsoft, Windows, Windows Server, Windows Vista, and MS-DOS are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Intel, Pentium, and Xeon are registered trademarks of Intel Corporation of the United States.
Regulatory Notices Regulatory Notices FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
The contents of this document may change without prior notice. Do not make copies or alter the document content without permission from NEC Corporation. Every effort has been made to ensure the completeness of this document. However, if you have any concerns, or discover errors or omissions, please contact your retailer.
Names and Functions of Parts in this document. Safety precautions Follow the instructions in this document for the safe use of the NEC Express server. This User’s Guide describes hazardous parts of the server, possible hazards, and how to avoid them. Server components with possible danger are indicated with a warning label placed on or around them (or, in some cases, by printing the warnings on the server).
Precautions for Use (Be Sure to Read) Symbols used in this document and on warning labels Attentions Indicates the presence of electric shock Indicates the presence of mechanical hazards. parts that can result in bodily injury. Indicates the presence of a hot surface or Indicates the presence of mechanical component.
Precautions for Use (Be Sure to Read) Safety notes This section provides notes on using the server safely. Read this section carefully to ensure proper and safe use of the server. For symbols, refer to Safety precautions. General WARNING Do not use the server for services where human life may be at stake or high reliability is required. This server is not intended for use in medical, nuclear, aerospace, mass transit or other applications where human life may be at stake or high reliability is required, nor is it intended for use in controlling such applications.
Precautions for Use (Be Sure to Read) Power supply and power cord use WARNING Do not hold the power plug with a wet hand. Do not disconnect/connect the plug while your hands are wet. Failure to follow this warning may cause an electric shock.
Page 17
Precautions for Use (Be Sure to Read) CAUTION Do not use any unauthorized interface cable. Use only the interface cables provided with the server. Electric current that exceeds the amount allowed could cause fire. Also, observe the following precautions to prevent electrical shock or fire caused by a damaged power cord.
Use only the specified interface cable. Use only interface cables provided by NEC and locate a proper device and connector before connecting a cable. Using an authorized cable or connecting a cable to an improper destination may cause a short circuit, resulting in a fire.
Precautions for Use (Be Sure to Read) Cleaning and working with internal devices WARNING Do not disassemble, repair, or alter the server. Never attempt to disassemble, repair, or alter the server on any occasion except as described in this document. Failure to follow this warning may cause not only malfunction of the server but also an electric shock or fire.
Precautions for Use (Be Sure to Read) During operation CAUTION Avoid contact with the server during thunderstorms. Do not touch any part of the server including the cables when a thunderstorm is approaching. Also, do not connect or disconnect any devices. There may be a risk of electric shock from lightning strike. Keep animals away from the server.
Precautions for Use (Be Sure to Read) Warning labels Warning labels are attached on or around potentially dangerous components (This label is either attached or printed on the component.) to draw attention from users to potential hazards involved in handling the server. (Do not remove or black out this label and keep it clean).
Precautions for Use (Be Sure to Read) Handling precautions for proper operations Be sure to observe the following precautions for the proper functioning of the server. Ignoring the precautions may cause server malfunction or failure. • Do not use any cell phone or PHS and switch off them near the server. Electric waves from such devices can cause server to malfunction.
Page 23
Disk devices: Approximately 2 to 3 hours Tape media: Approximately 1 day • For optional devices, we recommend you use our NEC products. Some memory or Hard Disk Drive manufactured by other companies are supported for use with this server, however, you will be charged to repair failure or damage caused by use of such products even within warranty period.
Page 24
Precautions for Use (Be Sure to Read) Tips for your health and safety Using a computer extensively may affect different parts of your body. Here are tips you should follow while working on a computer to minimize strain on your body. Keep proper posture The basic body position for using a computer is sitting straight with your hands on the keyboard parallel with the floor, and your eyes...
NEC Express5800 Series Express5800/GT110e General Description This chapter introduces the features of this server and the name of each part. 1. Introduction 2. Accessories Verify the condition of your server's accessories. 3. Standard Features Check and maintain the server system by using the functions explained in this section.
® Celeron processor NEC’s latest technology and architectures realize high-power and high-speed operation that cannot be matched by existing servers. The server is designed with consideration of not only reliability but also expandability, which enables you to use it as a network server.
Chapter 1 General Description 2. Accessories Accessories The carton box contains various accessories which are required for setup or maintenance. Make sure you have them all for future use. • Power cord • Keyboard • Mouse • Screws for additional hard disk drives •...
• BIOS password feature High availability • Monitors OS stalls using the Watchdog timer Management utilities • NEC ESMPRO • ExpressUpdate • Remote controlling featuer (EXPRESSSCOPE Engine 3) • RAID System management utility (Universal RAID Utility) • Hard disk drive monitoring Power saving and noiseless design •...
Page 29
Chapter 1 General Description 3. Standard Features Many built-in features • El Torito Bootable CD-ROM (no emulation mode) format supported • Software power-off • Remote power-on feature • AC-Link feature • Remote console feature • Power switch mask • Baseboard Management Controller (BMC) conforming to IPMI v2.0 Self-diagnosis •...
The hardware components of the server provide operation control/reliability features as shown below. Additionally, NEC ESMPRO Agent, which is provided in EXPRESSBUILDER, enables you to collectively manage the state of your systems. You can also monitor the server states from a PC to manage the network where NEC ESMPRO Manager provided in EXPRESSBUILDER is installed.
3. Standard Features Firmware and Software Version Management Use of NEC ESMPRO Manager and ExpressUpdate Agent allows you to manage versions of firmware and software as well as update them by applying update packages. This function automatically updates multiple modules without stopping the system just by specifying the application of an update package from NEC ESMPRO Manager.
Chapter 1 General Description 4. Names and Functions of Parts Names and Functions of Parts This chapter describes the names of the server parts. Front View (1) Front Bezel (5) Disk Access LED (green/amber) This cover protects the front part of the server. Open the This LED lights or flashes green when the internal hard disk upper door to access the optical disk drive or the bay.
Chapter 1 General Description 4. Names and Functions of Parts Rear View (10) (11) (13) (12) (1) AC Inlet (6) DUMP Switch (NMI) This socket is used to connect the power cord. Press this switch to obtain a memory dump. (2) Screws for fixing the side cover (2 screws) (7) BMC RESET Switch The screws that secure the side cover on the left.
Chapter 1 General Description 4. Names and Functions of Parts Internal View (11) (10) Power supply unit HDD cage DIMM slots Hard disk drive (option) Optical disk drive Motherboard 5.25-inch Expansion Bay Cooling fan (CPU) PCI Card Guide (10) PCI Retention Latch (11) Cooling fan (rear) Express5800/GT110e User’s Guide...
Page 35
Chapter 1 General Description 4. Names and Functions of Parts When optional 2.5-inch HDD cage is installed (11) (10) Power supply unit HDD cage DIMM slots Hard disk drive (option) Optical disk drive Motherboard 5.25-inch Expansion Bay Cooling fan (CPU) PCI Card Guide (10) PCI Retention Latch (11) Cooling fan (rear)
The following table lists STATUS LED patterns, their explanation and solution. Tips Refer to the system event log (SEL) by using NEC ESMPRO or the Offline Tool to view the cause of failure. Express5800/GT110e User’s Guide...
Page 38
Chapter 1 General Description 4. Names and Functions of Parts Status LED pattern Explanation Solution − On (green) Normal state Flashing (green) Memory is in a degraded state Identify the device in degraded state by using the BIOS setup utility SETUP, and replace it as soon as possible. An uncorrectable memory error has often occurred.
Chapter 1 General Description 4. Names and Functions of Parts 4.5.3 Disk Access LED ( Disk Access LED lights or flashes green when an internal hard disk drive or the optical disk drive is being accessed. When RAID System using an optional RAID Controller is configured, this LED lights amber if hard disk drive error occurs.
NEC Express5800 Series Express5800/GT110e Preparations This chapter describes preparations for using this server. 1. Installing Internal Optional Devices You can skip this section if you did not purchase any optional devices. 2. Installation and Connection You must place the server in an ideal location and connect some cables following this section.
• Use only the devices and cables specified by NEC. You will be charged to repair damages, malfunctions, and failures caused by the use of any devices or cables not specified for use with this server even within the warranty period.
Chapter 2 Preparations 1. Installing Internal Optional Devices Anti-static Measures The server contains electronic components sensitive to static electricity. Avoid failures caused by static electricity when installing or removing any optional devices. • Wear a wrist strap (an arm belt or anti-static glove) Wear a wrist strap on your wrist.
Chapter 2 Preparations 1. Installing Internal Optional Devices Overview of Installation and Removal Install/remove components by using the following procedure. • If the server is ON, turn it off. Refer to Chapter 3 (6. Turning Off the Server). • Disconnect the power cord from the outlet and the server. •...
Chapter 2 Preparations 1. Installing Internal Optional Devices Removing the Side Cover Remove the side cover by using the following procedure. Refer to steps 1 to 3 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Unlock the padlock attached to the chassis if applicable. Remove the two screws at the rear of the chassis.
Chapter 2 Preparations 1. Installing Internal Optional Devices Removing the Front Bezel Remove the front bezel by using the following procedure. Refer to steps 1 to 3 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Pull the three tabs on the front bezel () and then pull the front bezel forward until it comes off the frame ().
Chapter 2 Preparations 1. Installing Internal Optional Devices Internal Flash Memory This section describes the procedure for installing the Internal Flash Memory. Internal Flash Memory connector Installation 1.6.1 Install the Internal Flash Memory in the following procedure. Refer to steps 1 to 5 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Attach the Internal Flash Memory and fix it with the screw provided with the product.
Up to 32 GB (8 GB × 4) of memory can be installed. Important • Use only the DIMMs specified by NEC. Installing a DIMM from a third party may cause the server to fail. (You will be charged to repair failures or damages caused by the use of such products even within the warranty period.)
Chapter 2 Preparations 1. Installing Internal Optional Devices Maximum supported memory size 1.7.1 The maximum available memory size on the server depends on the architecture (x86 architecture) and OS specs. A list of maximum memory sizes The maximum memory size The maximum memory size supported on each OS supported on the server...
Chapter 2 Preparations 1. Installing Internal Optional Devices Installation 1.7.3 Install a DIMM by using the following procedure. Refer to steps 1 to 5 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Hold the server with both hands and slowly and gently lay it so that the left side faces upward Rotate both levers of the target DIMM slot outward.
• When removing a defective DIMM, check error messages displayed at POST or NEC ESMPRO and check the DIMM slot where the defective DIMM is installed. • At least one DIMM needs to be installed for the server to operate.
Chapter 2 Preparations 1. Installing Internal Optional Devices Use of Internal Hard Disk Drives in the RAID System This section describes how to use the Hard Disk Drives installed in the HDD cage at the front of the server in the RAID System.
Page 52
Chapter 2 Preparations 1. Installing Internal Optional Devices When using on-board RAID Controllers (LSI Embedded MegaRAID Change the jumper switch setting by using the following procedure. Refer to steps 1 to 5 in Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Remove the side cover while referring to Chapter 2 (1.4 Removing the Side Cover).
Chapter 2 Preparations 1. Installing Internal Optional Devices Notes on setting up a RAID System 1.8.1 Note the following points when setting up a RAID System. • The number of Hard Disk Drives required varies in each RAID level. • If an on-board RAID Controller or optional RAID Controller (N8103-128/149) is used, the RAID System cannot be built in RAID5/RAID6.
Page 54
Chapter 2 Preparations 1. Installing Internal Optional Devices Example: Slot numbers (SLT) for HDD and SSD displayed in OS system event log Slot number to install Slot numbers indicated Insert position numbers displayed Optional RAID Controllers On-board RAID Controllers on the server (N8103-128/149/150/151) SLT = 1 SLT = 1...
Chapter 2 Preparations 1. Installing Internal Optional Devices Extra Battery for RAID Controller If a RAID Controller (N8103-128/149/150/151) is installed, use the optional extra battery to avoid data loss caused by accidents including temporary blackout during a write-back operation. The model of the extra battery to be used depends on RAID Controller.
Page 56
Chapter 2 Preparations 1. Installing Internal Optional Devices Install the battery control cable supplied with the N8103-155 extra battery onto the RAID Controller. Tips For the installation procedure, refer to the user’s guide supplied with the extra battery. Refer to Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Remove the side cover while referring to Chapter 2 (1.4 Removing the Side Cover).
Page 57
Chapter 2 Preparations 1. Installing Internal Optional Devices Connect the battery control cable to the battery pack. Check the orientation of the connector and connect the cable straight into the connector. Orientation of the connector Orient the markings of the connector and cable to fit each other, and then connect them. Black marking Use the screw you removed in step 5 to install the battery unit.
Page 58
Chapter 2 Preparations 1. Installing Internal Optional Devices 10. Connect the RAID Controller board to the slot on the motherboard. 11. Put the removed components. Express5800/GT110e User’s Guide...
Chapter 2 Preparations 1. Installing Internal Optional Devices Installing N8103-141 extra battery 1.9.3 This section describes the procedure of installing an extra battery for RAID Controller. Install the connection board supplied with the N8103-141 extra battery onto the RAID Controller. Tips For the installation procedure, refer to the user’s guide supplied with the extra battery.
Chapter 2 Preparations 1. Installing Internal Optional Devices Connect the remote battery connection cable to the battery pack. Facing up the battery plate Blue line on the left Use the screw you removed in step 4 to install the battery unit. Connect the RAID Controller board to the slot on the motherboard.
Chapter 2 Preparations 1. Installing Internal Optional Devices 1.10 PCI Card This server provides four slots where PCI cards can be installed. Important • You must avoid static electricity to work with the procedure below. For details, refer to Chapter 2 (1.2 Anti-static Measures). •...
Chapter 2 Preparations 1. Installing Internal Optional Devices Notes 1.10.1 Read the following notes when installing or removing a PCI card. • Do not touch the terminals of the riser cards and the leads of electronic components with your bare hand.
Chapter 2 Preparations 1. Installing Internal Optional Devices List of option devices and installation slots 1.10.2 PCI EXPRESS PCI#1 PCI#2 PCI#3 PCI#4 32 bits/ PCI slot performance X4 lane X4 lane X16lane 33 MHz Product Model name Remarks name Slot size Full Height PCI card type socket...
Page 64
Chapter 2 Preparations 1. Installing Internal Optional Devices *1 Lane: Indicates the transfer performance (transfer bandwidth). <e.g.> 1 lane = 2.5 Gbps (unidirectional), 4 lanes = 10 Gbps (unidirectional) Socket: Indicates the connector size. A card up to the number of sockets can be connected. <e.g.>...
Chapter 2 Preparations 1. Installing Internal Optional Devices Installation 1.10.3 Install a PCI card to connect to a PCI slot by using the following procedure. For details, refer to the instruction manual supplied with your OS. Before installation, make sure the switch or jumper settings on the card are properly set according to the instruction manual supplied with the card if necessary.
Page 66
Chapter 2 Preparations 1. Installing Internal Optional Devices Orient the component side of the card toward the bottom of the server. When the rear panel of the card is firmly engaged with the spring, firmly press the card into the slot so that the component parts of the card securely connect to the slot.
Chapter 2 Preparations 1. Installing Internal Optional Devices Configuration after installing 1.10.4 Depending on the type of card installed, you might need to use a utility (the BIOS setup utility included with this server or a setup utility provided with the card) following installation to modify server settings. Follow the instructions in the manual provided with the card to specify the correct settings.
Chapter 2 Preparations 1. Installing Internal Optional Devices Installing the N8117-01A additional RS-232C connector kit 1.10.6 Install a PCI card to connect to the PCI slot by using the following procedure. For details, refer to the instruction manual supplied with the connector kit. Important The N8117-01A additional RS-232C connector kit contains two types of cables.
Page 69
Chapter 2 Preparations 1. Installing Internal Optional Devices Release the lock on the PCI card retention latch, and remove the blank cover. Important Keep the removed blank cover for future use. Make sure that you are properly inserting the bracket edge into the frame guide, and attach it securely.
Page 70
Chapter 2 Preparations 1. Installing Internal Optional Devices Bend the cable so as not to buffer other PCI cards, and connect to the COM connector used for internal connections in the motherboard. Refer to the following for the position of the COM connector for internal connections. Important If connecting the cable, fit it to the polarizing key of the connector and be careful not to connect it improperly.
A maximum of 4 SATA Hard Disk Drives can be internally installed to this device. Important Use Hard Disk Drives specified by NEC. Installing a third-party Hard Disk Drive might cause a failure of the server and the Hard Disk Drive. You will be charged for maintenance for failures and damage caused by these products, even during the maintenance period.
Chapter 2 Preparations 1. Installing Internal Optional Devices Installation 1.11.1 Follow the procedure below to install the 3.5-inch Hard Disk Drive. Refer to the manual provided with the Hard Disk Drive before installation, and specify the settings of the Hard Disk Drive. Number of Location of the bay Serial ATA connector of the...
Page 73
Chapter 2 Preparations 1. Installing Internal Optional Devices Remove the HDD cage from the server. Important • Be careful not to hit the motherboard components with the HDD cage. • Be careful not to pull on the cables when removing the HDD cage. Gently place the removed HDD cage onto a desk that has undergone anti-static treatment.
Page 74
Chapter 2 Preparations 1. Installing Internal Optional Devices 10. Fit the HDD cage guide rails to the hooks and insert the cage. Fit the guide rails of the bay to the hooks of the server Important • Be careful not to hit the motherboard components with the HDD cage. •...
Chapter 2 Preparations 1. Installing Internal Optional Devices Removal 1.11.2 You can remove the Hard Disk Drive by using the following procedure. Important If you dispose of the removed hard disk drive, follow instructrions described in Chapter 1 (1. Transfer, Movement, and Disposal) in “Maintenance Guide”.
Mount SATA/SAS hard drives in order from slot 0, and mount the SSDs to the remaining slots. Important Use Hard Disk Drives specified by NEC. Installing a third-party Hard Disk Drive might cause a failure of the server and the Hard Disk Drive. You will be charged for maintenance for failures and damage caused by these products, even during the maintenance period.
Chapter 2 Preparations 1. Installing Internal Optional Devices Replacing HDD cage 1.12.1 You can replace the HDD cage by using the following procedure. Refer to Chapter 2 (1.3 Overview of Installation and Removal) for preparations. Remove the side cover and front bezel while referring to Chapter 2 (1.4 Removing the Side Cover and 1.5 Removing the Front Bezel).
Page 78
Chapter 2 Preparations 1. Installing Internal Optional Devices Attach the bracket for 2.5-inch HDD cages. Use the two screws you removed in step 5 to fix the side cover. Use the two screws you removed in step 4 to fix the bracket at the side of the front panel.
Chapter 2 Preparations 1. Installing Internal Optional Devices 11. Use the four screws you removed in step 3 to fix the 2.5-inch HDD cage. This completes the replacement procedures for HDD cages. Installation 1.12.2 Follow the procedure below to install the 2.5-inch Hard Disk Drive. Refer to the manual provided with the Hard Disk Drive before installation, and specify the settings of the Hard Disk Drive.
Page 80
Chapter 2 Preparations 1. Installing Internal Optional Devices Remove the four screws securing the HDD cage. Remove the HDD cage from the server. Important • Be careful not to hit the motherboard components with the HDD cage. • Be careful not to pull on the cables when removing the Hard Disk Drive. Gently place the removed HDD cage onto a desk that has undergone anti-static treatment.
Page 81
Chapter 2 Preparations 1. Installing Internal Optional Devices 11. Fit the HDD cage guide rails to the support bracket guides and insert the cage. Fit the guide rails of the HDD cage to the guide of the support bracket Important •...
Chapter 2 Preparations 1. Installing Internal Optional Devices Removal 1.12.3 You can remove the Hard Disk Drive by using the following procedure. Important If you dispose of the removed hard disk drive, follow instructrions described in Chapter 1 (1. Transfer, Movement, and Disposal) in “Maintenance Guide”.
Procedures for replacing the standard optical disk drive with the optional internal DVD SuperMULTI drive are described below. Important Do not install a DVD SuperMULTI drive other than those specified by NEC. Replacing drives 1.13.1 Follow the procedure below to replace your drive with the optional internal DVD SuperMULTI drive.
Chapter 2 Preparations 1. Installing Internal Optional Devices Pull the optical disk drive out of the server and remove it. This completes the optical disk drive removal procedures. Insert the screw holes on the left side of the internal DVD SuperMULTI drive into the hooks described in step 5.
Chapter 2 Preparations 1. Installing Internal Optional Devices 1.14 File devices This server contains slots for the installation of backup devices, such as magnetic tape drives. As a standard, there are two expansion slots. Tips Controller board options and internal cables might be required depending on the devices installed.
Page 86
Chapter 2 Preparations 1. Installing Internal Optional Devices Hook your finger in the circular hole of the blank cover (the metal sheet covering the installation slots) in the file bay, and remove from the server. Important Keep the removed blank cover for future use. Remove the two special screws fixed to the front of the server.
Page 87
Chapter 2 Preparations 1. Installing Internal Optional Devices Attach the two screws you removed in step 5 to the right side of the file device. Tips • If installing N8151-90/101/102/103, put the plate for device that was provided with the server on the right side of the device and install it to the front of the server by using the two dedicated screws.
Chapter 2 Preparations 1. Installing Internal Optional Devices Orient the screw holes of the device with the screw holes of the server and attach them with the two screws (screw set 504) supplied with the server. Important Be sure to use the screws that were provided with the server (screw set 504) and not screws that were provided with the device.
Chapter 2 Preparations 1. Installing Internal Optional Devices 1.15 Connecting cables This section shows an example of internal device cable connection. Interface cables 1.15.1 This section describes the connection of interface cables. Tips The figure shown here primarily describes connections. For more information about the connectors on the motherboard, refer to Chapter 1 (5.4 Motherboard).
Page 90
Chapter 2 Preparations 1. Installing Internal Optional Devices If connecting an SAS Hard Disk Drive, SATA Hard Disk Drive, or a solid state drive to a RAID Controller Connecting to a RAID Controller requires an interface cable for use with RAID Controllers. If using a 2.5-inch Hard Disk Drive: K410-251(00) internal SAS/SATA cable If using a 3.5-inch Hard Disk Drive: K410-252(00) internal SAS/SATA cable Install the Hard Disk Drives in order from the bottom.
Page 91
Chapter 2 Preparations 1. Installing Internal Optional Devices Important • SAS Hard Disk Drives and SATA Hard Disk Drives cannot be combined. • About RAID LED cables The DISK access LED on the front of the equipment shows the access status of Hard Disk Drives that are connected to a RAID Controller.
Page 92
Chapter 2 Preparations 1. Installing Internal Optional Devices Connecting 5.25-inch devices You can mount SAS devices and USB devices (for internal connections) to 5.25-inch devices. If mounting an SAS device Power supply unit 5.25-inch device bay Optical disk drive Motherboard SAS controller SAS cable SATA cable...
Page 93
Chapter 2 Preparations 1. Installing Internal Optional Devices If mounting an internal USB device The K410-254(00) internal USB cable is used to connect the device. Power supply unit 5.25-inch device bay Optical disk drive Motherboard USB connector Internal USB cable SATA cable (K410-254(00)) (for use with the optical disk drive)
Chapter 2 Preparations 1. Installing Internal Optional Devices Power cables 1.15.2 The illustration below shows an example of connecting the power cables. Power cables other than those shown here are not used by the devices. If connecting Hard Disk Drives to an onboard SATA controller Power 5.25-inch supply unit...
Page 95
Chapter 2 Preparations 1. Installing Internal Optional Devices If connecting Hard Disk Drives to a RAID Controller Power supply unit Optional device 5.25-inch device bay Optional device Optical disk drive HDD 4 PWR_DET1 HDD 3 RAID Controller HDD 2 (N8103-128/149/150/151) HDD 1 Motherboard Power cable...
Chapter 2 Preparations 1. Installing Internal Optional Devices 1.16 Attaching the Front Bezel You can attach the front bezel by reversing the removal procedure. Insert the three tabs on the right side of the front bezel into the holes on the front of the server and then push the left side toward the server to lock by using the tabs.
Chapter 2 Preparations 1. Installing Internal Optional Devices 1.17 Installing the Side Cover You can attach the side cover by reversing the removal procedure. Make sure that hooks at both the top and bottom of the side cover are securely inserted in the holes on the server frame.
Chapter 2 Preparations 2. Installation and Connection Installation and Connection This section describes how to position the server and connect cables. Installation CAUTION Be sure to observe the following precautions to use the server safely. Failure to observe the precautions may cause burns, injury, and property damage. For details, refer to Safety precautions in Precautions for Use.
Page 99
Chapter 2 Preparations 2. Installation and Connection Do not install the server in an environment in which any of the following conditions apply: Installing the server in any of the following conditions will cause the server to malfunction. Places where corrosive gas is present (environments where there is sulfur vapor in the atmosphere), or places Place of drastic temperature change...
Chapter 2 Preparations 2. Installation and Connection Connection Connect peripheral devices to the server. Connectors that allow a variety of peripheral devices to be connected are provided at the front and rear of the server. Images on the following pages show the peripheral devices that can be connected in their standard state and their respective connector positions.
• The connectors that are not explained here are not used. Do not connect anything to the connectors. • Be sure to use the display unit specified by NEC. The operation is not guaranteed if you install a display unit not specified by NEC.
Page 102
Chapter 2 Preparations 2. Installation and Connection Front view USB devices, such as terminal adapters Rear view Finally, connect the provided power cord to an outlet. A device with serial interface (such as a modem) Display unit Hub/switching hub, etc. USB devices (such as a terminal adapter, mouse, and keyboard) Hub/switching hub, etc.
Chapter 2 Preparations 2. Installation and Connection Power cord 2.2.2 Connect the provided power cord to the server. Tips • To connect the power cord to a UPS, connect it to the outlet provided at the rear of the UPS. For details, refer to the instruction manual supplied with the UPS •...
NEC Express5800 Series Express5800/GT110e Setup This chapter describes how to set up the server. 1. Turning on the Server POST (Power-On Self-Test) is explained in this section. 2. System BIOS Setup You can customize BIOS settings by following the instructions in this section.
3. Press the POWER switch at the front of the server. The POWER LED is turned on green and after a while, the NEC logo appears on the display. While the NEC POWER logo is being displayed, the self-diagnostic program switch (POST) runs and diagnoses the hardware.
POST starts memory check. When the memory check is completed, some messages appear. As factory settings, the NEC logo appears on the screen during POST. 2. If the <Esc> key is pressed, the logo disappears and the details of POST are displayed.
Page 107
Chapter 3 Setup 1. Turning on the Server 4. After a while, the following message is displayed on the screen. Press <F2> SETUP, <F3> Internal Flash Memory, <F4> ROM Utility, <F12> Network By pressing the designated function key following messages, you can call the functions below upon completion of POST.
Chapter 3 Setup 1. Turning on the Server POST Error Messages 1.1.2 When POST detects an error, it displays an error message on the screen or beeps for some errors. For descriptions of error messages, causes, and countermeasures, refer to "Maintenance Guide". Important Take notes on the messages displayed before consulting with your maintenance service company.
If you press the <F2> key at this time, SETUP runs and displays the Main menu upon completion of POST. (You can also press the <F2> key while the NEC logo appears to display the Main menu.) Express5800/GT110e User’s Guide...
Chapter 3 Setup 2. System BIOS Setup Description on On-Screen Items and Key Usage This section shows display examples and how to control the key. Use the keyboard to work with the SETUP utility. Indicates the currently displayed menu Indicates the menu has submenus.
Page 111
Chapter 3 Setup 2. System BIOS Setup <F2> key If you press this key, the following window appears. If you select Yes, the previous parameter(s) are restored. Load Previous Values? [Yes] <F3> key If you press this key, the following window appears. If you select Yes, restore the parameters of the currently selected item to the default setting.
Boot → Bootup Numlock State Boot → Quite Boot → Disabled On/Off the function to display By pressing the <Esc> key, the NEC logo during POST prevent the display of the logo. Advanced → PCI Configuration → PCI Optional Install RAID Controller board...
Page 113
Chapter 3 Setup 2. System BIOS Setup Password If you have set a password, a message prompt you to enter password will be displayed from the next time. Enter password [ You can attempt password entry up to 3 times. If you entered a wrong password 3 times, operation stops. (You cannot operate further.) Turn off the power.
Chapter 3 Setup 3. EXPRESSSCOPE ENGINE 3 EXPRESSSCOPE ENGINE 3 Overview EXPRESSSCOPE Engine 3 provides a variety of features using BMC (Baseboard Management Controller), which is a system management LSI. EXPRESSSCOPE Engine 3 monitors the power unit, fans, temperature, and voltage of the server. If you have the management LAN port connected to the network, you can remotely perform the following over a web browser or SSH client: •...
2. If you press the <F4> key at this time, ROM utility starts upon completion of POST. You can also press the <F4> key while the NEC logo is being displayed to open the Off-line TOOL MENU screen. 3. The keyboard selection screen appears. Select your keyboard type.
Page 116
Chapter 3 Setup 3. EXPRESSSCOPE ENGINE 3 5. If Property is selected, the following screen is displayed. On this screen, specify whether to use DHCP and if DHCP is not used, configure IP Address/Subnet Mask. Tips If Shared BMC LAN is enabled, Web feature, remote media/KVM feature, or command line interface feature may be interrupted.
RAID configuration to installation of applications. To use this feature, (Windows reinstallation) select Os installation in the menu after boot. Storage of software* Stores various bundled software (such as NEC ESMPRO Agent). Maintenance Diagnoses your server system. To use this feature, select Tool menu in the menu after boot.
Chapter 3 Setup 6. Turning Off the Server Turning Off the Server Turn off the server by using the following procedure. If the power cord of the server is connected to a UPS, refer to the documentation supplied with the UPS or the documentation for the application controlling the UPS. Shut down the OS.
Chapter 4 Appendix 2. Interrupt Lines Interrupt Lines Interrupt lines are assigned as factory settings as shown below. Use this table as a reference when you add optional devices. • Interrupt lines As factory settings, interrupt lines are assigned as follows. Peripheral Device (Controller) Peripheral Device (Controller) System timer...
Need help?
Do you have a question about the Express5800/GT110e EXP280A and is the answer not in the manual?
Questions and answers