NEC N8100-1223F User Manual page 338

Express5800/140hf
Table of Contents

Advertisement

8-44 Troubleshooting
There are some cases that an event log shown below is registered in application log of Event
Viewer every time you power on the server.
Event Source: MR_MONITOR
Event Type:
Event ID:
Description: Controller ID:a Unexpected sense PD=b:255 , CDB=0x1c, ...,
a: Controller number of LSI Logic MegaRAID SAS PCI EXPRESS ROMB
Normally, the controller ID is "0". It depends on the number of disk array controller
cards N8103-90 installed in PCI-Express slot.
b: SAS port number of LSI Logic MegaRAID SAS PCI EXPRESS ROMB
(1: Port 0-3, 2: Port 4-7)
→ It is not a problem in operating the system.
During operation, there are some cases that a warning message concerning SAS device is
registered in MegaRAID Storage Manager (MSM) log.
Controller ID:a Unexpected sense PD=b:c , CDB=0xXX, ..., Sense=0xXX, ...
a: Controller number of LSI Logic MegaRAID SAS PCI EXPRESS ROMB
Normally, the controller ID is "0". It depends on the number of disk array controller
cards N8103-90 installed in PCI-Express slot.
b: SAS port number of LSI Logic MegaRAID SAS PCI EXPRESS ROMB
(1: Port 0-3, 2: Port 4-7)
c: Slot number for the device
This message indicates that the command issued to SAS device is abnormally ended.
→ Normally the command is retried, therefore, it is not a problem in operating the
system.
This message may be logged when SAS hard disk drive that has not been configured
is removed from the slot.
→ It is not a problem in operating the system.
If the message is displayed again for the specific hard disk drive, check if the hard
disk drive is connected correctly.
→ If the same error message appears repeatedly, contact your service representative
to replace the hard disk drive.
Warning
113
Sense=0x70, 0x00, 0x06, 0x00, 0x00, 0x00, 0x00, 0x0a, 0x00, 0x00,0x00,
0x00, 0x29,...

Advertisement

Table of Contents
loading

Table of Contents